2013
DOI: 10.1016/j.medengphy.2012.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Improving greater trochanteric reattachment with a novel cable plate system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 22 publications
0
4
0
1
Order By: Relevance
“…Todd et al (2007) have shown that locking screw performance could be independent of the bone mineral density (BMD) and also offer better primary fixation stability than the cable cerclages typically used (Cloutier et al, 2013). Previous studies have also shown that the novel locking plate with anterior fixations used in this study significantly reduces GT movements, but on synthetic specimens loaded in a quasistatic mode and without describing any failure mode (Baril et al, 2012(Baril et al, , 2013.…”
Section: Introductionmentioning
confidence: 72%
See 1 more Smart Citation
“…Todd et al (2007) have shown that locking screw performance could be independent of the bone mineral density (BMD) and also offer better primary fixation stability than the cable cerclages typically used (Cloutier et al, 2013). Previous studies have also shown that the novel locking plate with anterior fixations used in this study significantly reduces GT movements, but on synthetic specimens loaded in a quasistatic mode and without describing any failure mode (Baril et al, 2012(Baril et al, , 2013.…”
Section: Introductionmentioning
confidence: 72%
“…Previous biomechanical studies on GT implants were performed in a quasi-static mode (Baril et al, 2012(Baril et al, , 2013Dall and Miles, 1983;Hersh et al, 1996;Khanna et al, 2007;Markolf et al, 1979;Plausinis et al, 2003;Schwab et al, 2008;Thakur et al, 2008). The current study is innovative by simulating a quasi-dynamic full stair climbing gait (Heller et al, 2005) in an attempt to better approach and reproduce migrations seen in patients.…”
Section: Discussionmentioning
confidence: 99%
“…Anatomic reduction, which may be difficult to achieve, and sufficient plate length and number of cables should improve the union rate. New plate designs with locking screws may improve results [ [16] , [17] , [18] ].…”
Section: Discussionmentioning
confidence: 99%
“…Cable grip systems are preferred mostly due to their superior mechanical properties like better resistance to fatigue and higher yield and breaking strength [ 6 , 7 ]. But their bulky structure causes symptoms like pain and bursitis more often than other constructs [ 8 ]. Wire or cable breakage is also an important complication which might lead to trochanteric nonunion and revision surgery.…”
Section: Discussionmentioning
confidence: 99%