2019
DOI: 10.1016/j.radphyschem.2018.06.039
|View full text |Cite
|
Sign up to set email alerts
|

Improving image quality of Rhodnius prolixus head using different types of staining methods and synchrotron radiation phase contrast microtomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…For instance, a study has optimized the use of PTA for imaging of bumblebee brain structures, whereby PTA outperformed iodine and other staining solution in terms of resolution of microstructures, although iodine was faster to perfuse through the samples (Smith et al 2016). Comparing the advantage and disadvantages of different protocols present in the specialized literature, iodine makes it more suitable for studying whole insect specimens (Metscher 2009b;Du Plessis et al 2017;Sena et al 2019). Thus, it is important to balance the pros and cons of each staining method according to the type of sample, costs, time, and the resolution needed for the images.…”
Section: Discussionmentioning
confidence: 99%
“…For instance, a study has optimized the use of PTA for imaging of bumblebee brain structures, whereby PTA outperformed iodine and other staining solution in terms of resolution of microstructures, although iodine was faster to perfuse through the samples (Smith et al 2016). Comparing the advantage and disadvantages of different protocols present in the specialized literature, iodine makes it more suitable for studying whole insect specimens (Metscher 2009b;Du Plessis et al 2017;Sena et al 2019). Thus, it is important to balance the pros and cons of each staining method according to the type of sample, costs, time, and the resolution needed for the images.…”
Section: Discussionmentioning
confidence: 99%
“…For instance, a study has optimised the use of PTA for imaging of bumblebee brain structures, whereby PTA outperformed iodine and other staining solution in terms of resolution of micro-structures, although iodine was faster to perfuse through the samples (Smith et al 2016). Comparing the advantage and disadvantages of different protocols present in the specialized literature, iodine makes it more suitable for studying whole insect specimens (Metscher 2009b; Du Plessis et al 2017; Sena et al 2019). Thus, it is important to balance the pros and cons of each staining method according to the type of sample, costs, time, and the resolution needed for the images.…”
Section: Discussionmentioning
confidence: 99%
“…To improve results with synchrotron microtomography and a polychromatic beam, after 2018 it was developed a staining protocol described by Sena et al. that allowed a better visualisation and segmentation of the Rhodnius prolixus structures 15,16 …”
Section: Introductionmentioning
confidence: 99%
“…14 To improve results with synchrotron microtomography and a polychromatic beam, after 2018 it was developed a staining protocol described by Sena et al that allowed a better visualisation and segmentation of the Rhodnius prolixus structures. 15,16 Some studies using laboratory microtomography conventional scanners combining with the correct staining methods have proved to be a powerful tool in biological research, allowing the visualisation of low-density tissues. [17][18][19][20] The main goal of the present work was to use staining protocols to study Rhodnius prolixus head anatomy with laboratory microtomography conventional scanners.…”
Section: Introductionmentioning
confidence: 99%