Improving Sustainability of the Griess Reaction by Reagent Stabilization on PDMS Membranes and ZnNPs as Reductor of Nitrates: Application to Different Water Samples

Abstract: A new approach based on the use of polydimethylsiloxane (PDMS) membranes doped with Griess reagents for in situ determination of NO2− and NO3−- in real samples is proposed. The influence of some doping compounds, on the properties of the PDMS membranes, such as tetraethyl orthosilicate (TEOS), or/and ionic liquids (OMIM PF6) has been studied. Membrane characterization was performed. To apply the procedure to NO3− determination, dispersed Zn nanoparticles (ZnNPs) were employed. The analytical responses were the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…Nitrate levels were measured using the Griess assay. 18 , 19 For this purpose, 100 μL of the cultured medium was incubated for 10 min with 100 μL of a solution of 1% (w/v) sulfanilic acid (Sigma, St. Louis, MO, USA)/0.1% (w/v) N-(1-naphtyl) ethylenediamine dihydrochloride (Sigma, St. Louis, MO, USA) in 2.5% (v/v) H 3 PO 4 . A sodium nitrate (Sigma, St. Louis, MO, USA) solution in the concentration range from 1.95 to 250 μM was used to prepare the calibration curve.…”
Section: Methodsmentioning
confidence: 99%
“…Nitrate levels were measured using the Griess assay. 18 , 19 For this purpose, 100 μL of the cultured medium was incubated for 10 min with 100 μL of a solution of 1% (w/v) sulfanilic acid (Sigma, St. Louis, MO, USA)/0.1% (w/v) N-(1-naphtyl) ethylenediamine dihydrochloride (Sigma, St. Louis, MO, USA) in 2.5% (v/v) H 3 PO 4 . A sodium nitrate (Sigma, St. Louis, MO, USA) solution in the concentration range from 1.95 to 250 μM was used to prepare the calibration curve.…”
Section: Methodsmentioning
confidence: 99%
“…The microplate was then shacked for t = 10 min at room temperature. Then, measurements were performed [ 25 ] (see Figure 1 c).…”
Section: Methodsmentioning
confidence: 99%
“…Certain organic and chemical compounds also can interfere with the Griess reaction, leading to inaccurate nitrite measurements that may appear as false positives. 19 Addressing the above limitations, there is a need for the development of a simple, stable, and affordable analytical device capable of quantitatively monitoring both bacteria and NO 2 − levels in water samples. Such a device would be highly beneficial and practical for ensuring water safety and quality assessment in a wide range of settings.…”
mentioning
confidence: 99%
“…Although this reaction is sensitive and commonly used for NO 2 – quantification, it is an unstable reagent which needs to be kept at low temperature, reducing its shelf life. Certain organic and chemical compounds also can interfere with the Griess reaction, leading to inaccurate nitrite measurements that may appear as false positives . Addressing the above limitations, there is a need for the development of a simple, stable, and affordable analytical device capable of quantitatively monitoring both bacteria and NO 2 – levels in water samples.…”
mentioning
confidence: 99%