2011
DOI: 10.1080/00032719.2010.500787
|View full text |Cite
|
Sign up to set email alerts
|

Improving the Detectability of Sequential Injection Chromatography (SIC): Determination of Triazines by Exploiting Liquid Core Waveguide (LCW) Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 20 publications
0
8
0
1
Order By: Relevance
“…The use of short MCs in SIC also contributes to the reduction of consumed volumes of mobile phase. As shown in Table 2, the waste production in SIC methods were in the range of 2.21-5.00 mL with two exceptions, 13.20 mL (Infante et al, 2011) and 11.53 mL (Elgorashe et al, in print). These volumes included the consumed volumes of mobile phase for both column conditioning and separation as well as sample volumes.…”
Section: Analytical Resultsmentioning
confidence: 95%
See 1 more Smart Citation
“…The use of short MCs in SIC also contributes to the reduction of consumed volumes of mobile phase. As shown in Table 2, the waste production in SIC methods were in the range of 2.21-5.00 mL with two exceptions, 13.20 mL (Infante et al, 2011) and 11.53 mL (Elgorashe et al, in print). These volumes included the consumed volumes of mobile phase for both column conditioning and separation as well as sample volumes.…”
Section: Analytical Resultsmentioning
confidence: 95%
“…Those FCs lowered the limit of detection (LOD) for poor UV absorbents compared Schematic diagram of a sequential injection chromatograph constructed for on-line filtration, dilution, and separation.that of a conventional short-distance FC Infante et al (2011). also proposed the use of an FC with a very long path length (100 mm).…”
mentioning
confidence: 98%
“…The FIAlab 5.1 software synchronized the movements of the syringe pump and the selection valve (Figure ) as well as aquired data from the UV detector. Details on the instrument configuration and mode of operation are described elsewhere. , …”
Section: Methodsmentioning
confidence: 99%
“…Sequential injection chromatography has been mostly applied to pharmaceutical and biological samples [10,11], although some few works have demonstrated its applicability to environmental analysis [12][13][14][15]. Atrazine (AT) and simazine (SIM) are herbicides widely used to stop pre-and post-emergence of broadleaf and grassy weeds in major crops such as sugar cane, maize, soybean and citrus fruits [16].…”
Section: Introductionmentioning
confidence: 99%