2012
DOI: 10.1016/j.memsci.2012.02.051
|View full text |Cite
|
Sign up to set email alerts
|

In-line coagulation prior to UF of treated domestic wastewater – foulants removal, fouling control and phosphorus removal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
25
0
5

Year Published

2013
2013
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 49 publications
(33 citation statements)
references
References 30 publications
2
25
0
5
Order By: Relevance
“…The effluent from the secondary clarifier was used as feed water directly to the pilot UF after a pre-filter with a pore size of 100 µm, and for the lab-scale UF test after pre-filtration using cellulose nitrate filter with a pore size of 0.45 µm (Satorious). More detailed information about the plant can be found in previous studies [23].…”
Section: Secondary Effluentmentioning
confidence: 99%
See 2 more Smart Citations
“…The effluent from the secondary clarifier was used as feed water directly to the pilot UF after a pre-filter with a pore size of 100 µm, and for the lab-scale UF test after pre-filtration using cellulose nitrate filter with a pore size of 0.45 µm (Satorious). More detailed information about the plant can be found in previous studies [23].…”
Section: Secondary Effluentmentioning
confidence: 99%
“…Pilot scale investigations were carried out using a dead-end pressure driven UF pilot plant with hydrophilized PES membranes (hollow fibre membrane, Dizzer 450, Inge AG, Inge, Greifenberg, Germany) after a pre-filter (100 µm mesh size) with no coagulant was used. Detailed information about the membrane can be found in a previous study [23]. In the present work, the UF unit was operated in dead-end filtration mode at a constant flux of 60 L/(m 2 ·h).…”
Section: Lab Scale Uf Testmentioning
confidence: 99%
See 1 more Smart Citation
“…Aluminum chloride (AlCl 3 ) and polyaluminum chloride (PACl) are widely used as coagulants in water treatment processes [11][12][13][14]. Researchers believe that PACl is superior to traditional aluminum coagulants for the removal of turbidity and dissolved organic matter [15], resulting in a number of studies focused on the performance of different aluminum species [16][17][18].…”
Section: Introductionmentioning
confidence: 99%
“…Over the past few decades, coagulation/flocculation was widely used as a pretreatment step of microfiltration and ultrafiltration for water treatment [6,[19][20][21]. Kim et al [22] suggested that coagulation can improve the membrane flux and mitigate fouling by changing particle characteristics at low aluminum dosage and reducing the foulants loading at high aluminum dosage.…”
Section: Introductionmentioning
confidence: 99%