2022
DOI: 10.1016/j.chroma.2022.463459
|View full text |Cite
|
Sign up to set email alerts
|

In situ anchor of multi-walled carbon nanotubes into iron-based metal-organic frameworks for enhanced adsorption of polycyclic aromatic hydrocarbons by magnetic solid-phase extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 34 publications
0
6
0
Order By: Relevance
“…The performance of SPE-GC-FID was compared to that of other related extraction techniques for the analysis of PAHs in terms of sample volume, solvent volume, LOD, linear range, precision, and extraction time (Table 2). 30,36–42 The results show that the precision and linear range of the proposed method are better or comparable with other methods. Also, the SPE-GC-FID method has lower LOD than MSPE/GC-FID (MGO@HMDI@β-CD), 36 MSPE/GC-FID (Fe 3 O 4 @ CNT@β-CD), 37 MSPE/GC-FID (G/Fe 3 O 4 @PT), 38 SPE-HPLC-UV (Graphene quantum dots-eggshell), 39 SPE-HPLC-FLD (Natural cotton fibers), 40 MSPE/HPLC-UV (MIL-101 (γ-Fe 2 O 3 )/MWCNT), 41 and comparable with SPME/GC-FID (Ppy/MnO 2 -fGr/[AVIm]NTf 2 ), 30 and MSPE/GC-MS/MS (MNPs@PAMAM-G2.0@GO).…”
Section: Resultsmentioning
confidence: 79%
See 1 more Smart Citation
“…The performance of SPE-GC-FID was compared to that of other related extraction techniques for the analysis of PAHs in terms of sample volume, solvent volume, LOD, linear range, precision, and extraction time (Table 2). 30,36–42 The results show that the precision and linear range of the proposed method are better or comparable with other methods. Also, the SPE-GC-FID method has lower LOD than MSPE/GC-FID (MGO@HMDI@β-CD), 36 MSPE/GC-FID (Fe 3 O 4 @ CNT@β-CD), 37 MSPE/GC-FID (G/Fe 3 O 4 @PT), 38 SPE-HPLC-UV (Graphene quantum dots-eggshell), 39 SPE-HPLC-FLD (Natural cotton fibers), 40 MSPE/HPLC-UV (MIL-101 (γ-Fe 2 O 3 )/MWCNT), 41 and comparable with SPME/GC-FID (Ppy/MnO 2 -fGr/[AVIm]NTf 2 ), 30 and MSPE/GC-MS/MS (MNPs@PAMAM-G2.0@GO).…”
Section: Resultsmentioning
confidence: 79%
“…30,36–42 The results show that the precision and linear range of the proposed method are better or comparable with other methods. Also, the SPE-GC-FID method has lower LOD than MSPE/GC-FID (MGO@HMDI@β-CD), 36 MSPE/GC-FID (Fe 3 O 4 @ CNT@β-CD), 37 MSPE/GC-FID (G/Fe 3 O 4 @PT), 38 SPE-HPLC-UV (Graphene quantum dots-eggshell), 39 SPE-HPLC-FLD (Natural cotton fibers), 40 MSPE/HPLC-UV (MIL-101 (γ-Fe 2 O 3 )/MWCNT), 41 and comparable with SPME/GC-FID (Ppy/MnO 2 -fGr/[AVIm]NTf 2 ), 30 and MSPE/GC-MS/MS (MNPs@PAMAM-G2.0@GO). 42 Lower organic solvent consumption and extraction time indicated that the SPE-GC-FID method using PPy/CNT coated stainless steel meshes as the sorbent is more efficient and rapid.…”
Section: Resultsmentioning
confidence: 79%
“…The lowest detection limit in this method was 0.0015 μg/L for PAEs and 0.0003 μg/L for PAHs. Most studies have reported minimum limits of detection (LODs) to be greater than 0.005 g/L for PAEs [ 37 , 38 , 39 ] and 0.2 μg/L for PAHs [ 40 , 41 , 42 ], and the linear range of the proposed method is wider than that of other methods for the detection of PAEs and PAHs. The advantages of this work are (1) the detection of human placental tissue, (2) sophisticated detection instrumentation and inexpensive extraction reagents, and (3) combined extraction and detection of PAHs and PAEs in large quantities.…”
Section: Discussionmentioning
confidence: 99%
“…MPC has the characteristics of superparamagnetism and large pore volume and it retains features of the MOF even after calcination. 22 Fe-containing MILs are a class of common MOFs which have strong adsorption properties and abundant active metal sites, 23 and the ordered arrangement of metal ions in MOFs can avoid the agglomeration of magnetic particles and increase the dispersion property effectively. 24…”
Section: Introductionmentioning
confidence: 99%
“…MPC has the characteristics of superparamagnetism and large pore volume and it retains features of the MOF even after calcination. 22 Fe-containing MILs are a class of common MOFs which have strong adsorption properties and abundant active metal sites, 23 and the ordered arrangement of metal ions in MOFs can avoid the agglomeration of magnetic particles and increase the dispersion property effectively. 24 Besides MPC calcined from various MOFs, multi-walled carbon nanotubes (MWCNTs), graphene oxide (GO) and their composite with other nanomaterials are some of the extensively used carbon materials in the extraction field, as they possess large specific surface area, abundant π-delocalized electrons and good thermal stability.…”
Section: Introductionmentioning
confidence: 99%