Proceedings of EuroSun 2018 2018
DOI: 10.18086/eurosun2018.12.01
|View full text |Cite
|
Sign up to set email alerts
|

In Situ Characterization of Thermal Collectors in Field Installations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Very short averaging times or instantaneous data are hardly suitable for this method. With sufficiently long averaging times, fluctuation limits of up to 5K in the input temperature and up to 15% in the mass flow could be allowed and led to good results (Fahr et al, 2018).…”
Section: Methodsmentioning
confidence: 99%
“…Very short averaging times or instantaneous data are hardly suitable for this method. With sufficiently long averaging times, fluctuation limits of up to 5K in the input temperature and up to 15% in the mass flow could be allowed and led to good results (Fahr et al, 2018).…”
Section: Methodsmentioning
confidence: 99%
“…Very short averaging times or instantaneous data are hardly suitable for this method. With sufficiently long averaging times, fluctuation limits of up to 5K in the input temperature and up to 15% in the mass flow could be allowed and led to good results [10]. All sequences with potential shadowing are excluded from the measurement based on geometrical calculations.…”
Section: Boundary Conditions Of the Measurementmentioning
confidence: 99%
“…), in-situ testing of collectors to build systematic knowledge on the "real-world" performance is important. This is currently investigated in the research projects MeQuSo [44] and ZeKon in-situ [45].…”
Section: Solar Yield Prediction and Performance Guaranteesmentioning
confidence: 99%