2005
DOI: 10.1149/1.1828272
|View full text |Cite
|
Sign up to set email alerts
|

In Situ Micro-Raman on the Membrane in a Working PEM Cell

Abstract: An electrochemical cell has been designed for in situ micro-Raman measurements on the polymer membrane in an operating polymer electrolyte cell ͑PEM͒. The method is applicable to studies of both the distribution of water and membrane structure in the working cell environment. An initial study of the water distribution across a Nafion 117 membrane in a cell working as a H 2 /H 2 pump cell at hydrogen flow and currents from 0 to 300 mA/cm 2 is presented. The results show that a hydration profile with a lower wat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
39
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(39 citation statements)
references
References 21 publications
0
39
0
Order By: Relevance
“…[28][29][30] Although there are reports of operando PEM fuel cell water management/transport studies, [31][32][33][34][35][36] no potential-dependent data was provided. This H 2 /air fuel cell spectroscopy uses density functional theory (DFT) calculated normal mode analysis of the Nafion side chain and perfluorinated small molecules to correlate variation of MEA Preparation.-Nafion 117 (Wilmington, DE) was pretreated by immersing sheets in boiling 8 M nitric acid followed by two hours in boiling Nanopure TM water.…”
mentioning
confidence: 99%
“…[28][29][30] Although there are reports of operando PEM fuel cell water management/transport studies, [31][32][33][34][35][36] no potential-dependent data was provided. This H 2 /air fuel cell spectroscopy uses density functional theory (DFT) calculated normal mode analysis of the Nafion side chain and perfluorinated small molecules to correlate variation of MEA Preparation.-Nafion 117 (Wilmington, DE) was pretreated by immersing sheets in boiling 8 M nitric acid followed by two hours in boiling Nanopure TM water.…”
mentioning
confidence: 99%
“…X-ray techniques, [18,19] small-angle neutron scattering (SANS), [20] magnetic-resonance imaging [21][22][23] and micro-Raman, [24] neutron radiography, [25] electrical-resistance measurements, [26][27][28][29] infrared absorption [30] and fluorescence spectroscopy [31] have been used for this purpose. Unfortunately, if one excludes micro-Raman measurements, [24] all of these techniques exhibit rather low spatial resolutions (if any). Moreover, they have other severe limitations, such as slow response to the hydration-degree variations, weak signals (resulting in poor accuracy), and only indirect dependence on the quantity of interest.…”
mentioning
confidence: 99%
“…As far as we know, the first in situ Raman measurement of water concentration profiles crossing the membrane thickness under dynamic transport condition was reported by Matic et al [82] in 2005. A Nafion 117 membrane was placed in a H 2 /H 2 pump electrochemical cell and spectra were collected on the edge, in the cross-section mode (see Figure 2).…”
Section: Resultsmentioning
confidence: 99%