2010
DOI: 10.1016/s0022-3913(10)60111-4
|View full text |Cite
|
Sign up to set email alerts
|

In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

12
225
3
18

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 233 publications
(258 citation statements)
references
References 19 publications
12
225
3
18
Order By: Relevance
“…38 These findings can provide understanding for the results of the current study, as the bond strength of LU to composite resin is expected to be better than that found with ceramics. 39,40 The presence of resin matrix in LU blocks should facilitate bonding to resin composite luting materials, resulting in more uniform stress distribution when compared to feldspathic and reinforced ceramics and therefore better fracture resistance. It is worth mentioning that although the application of a single monotonic load to cause failure does not represent the clinical situation, in which repetitive cyclic fatigue loading is characteristic, the setting of this study provided a controlled environment that allows comparing the behavior of materials under the applied circumstances.…”
Section: Discussionmentioning
confidence: 99%
“…38 These findings can provide understanding for the results of the current study, as the bond strength of LU to composite resin is expected to be better than that found with ceramics. 39,40 The presence of resin matrix in LU blocks should facilitate bonding to resin composite luting materials, resulting in more uniform stress distribution when compared to feldspathic and reinforced ceramics and therefore better fracture resistance. It is worth mentioning that although the application of a single monotonic load to cause failure does not represent the clinical situation, in which repetitive cyclic fatigue loading is characteristic, the setting of this study provided a controlled environment that allows comparing the behavior of materials under the applied circumstances.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, biomechanical tests that simulate the oral environment by reproduction of the chewing forces, temperature and humidity of the oral cavity are important in evaluating the performance of new materials (8). Fatigue testing meets these requirements and is used for testing dental materials like composite resins and ceramics (9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21). The fatigue test simulates the clinical situation better than static compression test (11).…”
Section: Discussionmentioning
confidence: 99%
“…Literature reports have shown that materials that exhibit high initial resistance do not always have high resistance to fatigue (5,6). Therefore, it seems appropriate that the strength of teeth restored with dental materials should be measured using a dynamic mechanical test rather than static tests (6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24).…”
Section: Introductionmentioning
confidence: 99%
“…damping effects, composite-based reconstructions are finding increased application, especially in implant borne restorations 1,2) . Industrial manufacturing of CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) blanks for composite and PMMAbased reconstructions was shown to significantly improve mechanical properties [3][4][5] .…”
Section: Introductionmentioning
confidence: 99%