2014
DOI: 10.1016/j.ijom.2013.10.008
|View full text |Cite
|
Sign up to set email alerts
|

In vitro mechanical assessment of 2.0-mm system three-dimensional miniplates in anterior mandibular fractures

Abstract: Abstract. This study constituted a comparative assessment of the mechanical resistance of square and rectangular 2.0-mm system three-dimensional miniplates as compared to the standard configuration using two straight miniplates. 90 polyurethane replica mandibles were used for the mechanical trials. Groups 1, 2, and 3 simulated complete symphyseal fractures characterized by linear separation of the central incisors; groups 4, 5, and 6 simulated parasymphyseal fractures with an oblique configuration. Groups 1 an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 35 publications
0
4
0
2
Order By: Relevance
“…Management of anterior mandibular fracture in literature shows variety of options for reduction and fixation, such as lag screws, double miniplates, reconstruction plates and using arch bar with single miniplate or lag screw (11)(12)(13). These are classified to be rigid or functionally stable methods as they allow early function and decreases the intra-fragmentary mobility.…”
Section: Discussionmentioning
confidence: 99%
“…Management of anterior mandibular fracture in literature shows variety of options for reduction and fixation, such as lag screws, double miniplates, reconstruction plates and using arch bar with single miniplate or lag screw (11)(12)(13). These are classified to be rigid or functionally stable methods as they allow early function and decreases the intra-fragmentary mobility.…”
Section: Discussionmentioning
confidence: 99%
“…It is more difficult to get a perfect adaptation with the 3D plates than with the linear ones because they are objects in the form of a plane that need to be adapted to a curved surface and not just an object in the form of a straight line. 11 Therefore, we undertook a study to compare the efficiency of 3 D miniplates and conventional Miniplates in the management of mandibular fractures in the interangular region on the basis of bite force and other clinical parameters.…”
Section: Discussionmentioning
confidence: 99%
“…Una limitación en el uso de la placa 3D 2-by-2 esta en que la posición de la placa no siempre puede mantener paralela la barra de la placa con la línea de la fractura, lo que limitaría la eficiencia de su uso. Esta conclusión también fue señalada recientemente por de Oliveira et al (2014), quienes en un trabajo in vitro demostraron menor eficiencia del soporte mecánico del sistema 3D 2-by-2 en el caso de fracturas oblicuas de sínfisis. Esta limitación puede ser disminuida cuando se aumenta la cantidad de tornillos incluidos en la placa 3D como ha sido presentado en algunas series de casos.…”
Section: Consideraciones Actualesunclassified
“…En las consideraciones mecánica de estudios in vitro que analizan los diferentes sistemas (placas de mayor y menor tamaño, tornillos compresivos, placas 3D) en fracturas de sínfisis mandibular no se han observado diferencias importantes en el desplazamiento de la fractura a la carga vertical (Feledy et al, 2004;Vieira e Oliveira & Passeri;de Oliveira et al). Lovald et al (2010), en un estudio con análisis finito, presentó resultados favorables en la distribución de tensiones en los tornillos cuando fueron empleados en placas 3D, utilizando un diseño tipo "X" modificado, mediante sistema con instalación de 8 tornillos.…”
Section: Consideraciones Actualesunclassified