In vitro optical quality measurements of three intraocular lens models having identical platform

Abstract: BackgroundWith recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The study included two diffractive multifocal IOLs, a bifocal and a trifocal one, as well as a monofocal IOL.MethodsThree IOL … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
34
0
4

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 45 publications
(38 citation statements)
references
References 29 publications
0
34
0
4
Order By: Relevance
“…The optical performance of the IOLs was evaluated using the optical bench OptiSpheric IOL Pro II (Trioptics GmbH, Germany), as described in previous studies [13][14][15][16][17][18][19]. Its measurement principles adhere to the guidelines governed by the International Standard Organization (ISO) 11979-2 [20] and 11979-9 [21,22] and it thus includes a model cornea (spherical aberration: 0.28 μm) and a model eye containing a balanced salt solution with a refractive index of 1.336 at 25˚C.…”
Section: Optical Quality Evaluationmentioning
confidence: 99%
“…The optical performance of the IOLs was evaluated using the optical bench OptiSpheric IOL Pro II (Trioptics GmbH, Germany), as described in previous studies [13][14][15][16][17][18][19]. Its measurement principles adhere to the guidelines governed by the International Standard Organization (ISO) 11979-2 [20] and 11979-9 [21,22] and it thus includes a model cornea (spherical aberration: 0.28 μm) and a model eye containing a balanced salt solution with a refractive index of 1.336 at 25˚C.…”
Section: Optical Quality Evaluationmentioning
confidence: 99%
“…For example, the Symfony IOL is composed of a hydrophobic acrylic material and has a refractive index of 1.47 and an Abbe number of 55. Similarly, the optical platform of the AT LARA IOL is based on its predecessors, which is made of hydrophilic-acrylic material with hydrophobic surface properties and has a refractive index of 1.46 and an Abbe number of 56.5 [9]. Furthermore, both EDOF IOLs use diffractive optical principles to effectively reduce the levels of longitudinal chromatic aberration [16,17].…”
Section: Discussionmentioning
confidence: 99%
“…The initial presbyopia-correcting IOLs were bifocal, providing functional vision at far and near distances [3,6]. The subsequent development of trifocal IOLs allowed visual restoration in intermediate distance as well, enabling patients to use computers or tablets without spectacles [7][8][9]. CA, USA) and the EDOF AT LARA® 829MP (Carl Zeiss Meditec, Jena, Germany) IOLs.…”
Section: Introductionmentioning
confidence: 99%
“…Die Implantation multifokaler Intraokularlinsen (IOL) in den Kapselsack kann Patienten Brillenunabhängigkeit in mehreren Distanzen ermöglichen [13].…”
Section: Trifokale Optikenunclassified