In vitro splint rigidity evaluation - comparison of a dynamic and a static measuring method

Abstract: The Periotest and vertical Zwick values are highly reproducible. The measurements of the two methods do not correlate; therefore, a conversion of Periotest values into metric displacement data is not feasible. The two methods provide different valuable information about tooth mobility. The Periotest method describes the damping characteristics of the periodontal ligament while the Zwick method reveals quantitative metric values.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
44
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(44 citation statements)
references
References 30 publications
0
44
0
Order By: Relevance
“…Previous studies evaluated splint rigidity in vitro using an artificial model (1,13,19). The advantages of artificial models are continuous availability, low to moderate inter-individual variability, and the ability to simulate physiologic and increased tooth mobility.…”
Section: Methodological Factorsmentioning
confidence: 99%
See 3 more Smart Citations
“…Previous studies evaluated splint rigidity in vitro using an artificial model (1,13,19). The advantages of artificial models are continuous availability, low to moderate inter-individual variability, and the ability to simulate physiologic and increased tooth mobility.…”
Section: Methodological Factorsmentioning
confidence: 99%
“…Before inserting a splint, the middle part of the vestibular enamel surface of the tooth facets was etched for 15 s (Sealbond II Etching; RTD) and bonded (1,2,13,19). All measurements were consecutively repeated three times per tooth, in the same sequence (tooth 12, 11, 21, 22) ( Fig.…”
Section: Splintingmentioning
confidence: 99%
See 2 more Smart Citations
“…Additionally, application of the Periotest is limited by the confined intraoral environment. The manufacturer's instructions for measuring PTVs suggest that the handpiece should be held at the correct angle and position to the target tooth, because the reading from the Periotest is considerably affected by tapping direction and position (7,12,13). However, these recommendations are difficult to implement when assessing posterior teeth (11).…”
Section: Introductionmentioning
confidence: 99%