1999
DOI: 10.1093/ndt/14.12.2922
|View full text |Cite
|
Sign up to set email alerts
|

In vitro study of r-hirudin permeability through membranes of different haemodialysers

Abstract: Only low-flux dialysers with polysulfone or regenerated cellulose membranes proved to be suitable for r-hirudin use in routine haemodialysis therapy. Other low-flux, and all high-flux, capillaries are permeable to r-hirudin and offer the possibility of lowering toxic r-hirudin concentrations after overdosing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
37
1

Year Published

2000
2000
2007
2007

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(41 citation statements)
references
References 15 publications
3
37
1
Order By: Relevance
“…Comparable SC were recently reported for PS and PA high-flux hemodialyzer membranes in a similar setup, albeit at markedly higher hirudin concentrations (15 to 18 g/ml) based on an in vitro circulation period of 30 min (13). A recent study determined so-called hirudin permeability factors of 19 hemodialyzer membranes in vitro (10). The in vitro setup, which did not allow for constant filtrate flow because of sealing of the filtrate space, the hirudin concentrations applied (30 to 50 g/ml, far beyond the clinically suitable range), and the way hirudin permeability was determined (only two pairs of hirudin concentration blood/ filtrate per hemodialyzer), render the direct transfer of the respective results to clinical hemofiltration difficult.…”
Section: Discussionmentioning
confidence: 75%
See 2 more Smart Citations
“…Comparable SC were recently reported for PS and PA high-flux hemodialyzer membranes in a similar setup, albeit at markedly higher hirudin concentrations (15 to 18 g/ml) based on an in vitro circulation period of 30 min (13). A recent study determined so-called hirudin permeability factors of 19 hemodialyzer membranes in vitro (10). The in vitro setup, which did not allow for constant filtrate flow because of sealing of the filtrate space, the hirudin concentrations applied (30 to 50 g/ml, far beyond the clinically suitable range), and the way hirudin permeability was determined (only two pairs of hirudin concentration blood/ filtrate per hemodialyzer), render the direct transfer of the respective results to clinical hemofiltration difficult.…”
Section: Discussionmentioning
confidence: 75%
“…The experimental design did not allow determination of SC according to standard methods. However, all high-flux hemodialyzer membranes tested showed significant hirudin permeability (10).…”
Section: Discussionmentioning
confidence: 91%
See 1 more Smart Citation
“…In vitro, lowflux dialyzers have been shown to be only partially permeable or impermeable, whereas high-flux dialyzers were permeable to lepirudin. 11,12 In vivo, using intermittent hemodialysis, however, lepirudin elimination was not enhanced by the use of highflux dialyzers. 5 Hemofiltration using continuous renal replacement therapy with continuous venovenous hemofiltration/dialysis with high-flux dialyzers has been shown to enhance lepirudin removal requiring increased dosages for maintenance of adequate anticoagulation.…”
Section: Discussionmentioning
confidence: 99%
“…10 Use of continuous hemofiltration with high-flux dialyzers has been advocated in lepirudin overdose situations. 11 We initiated therapy at the lower range of doses reported by Vanholder et al 5 of 0.025 mg/kg following an initial bolus dose of 0.1 mg/kg. Our decision was based on: 1) inability to reverse anticoagulant effects (no antidote, questionable removal with hemodialysis); and 2) increased risk of major bleeding (liver dysfunction and other comorbidities).…”
Section: Discussionmentioning
confidence: 99%