2005
DOI: 10.1002/jmri.20275
|View full text |Cite
|
Sign up to set email alerts
|

In vitro validation of phase‐contrast flow measurements at 3 T in comparison to 1.5 T: Precision, accuracy, and signal‐to‐noise ratios

Abstract: Purpose:To evaluate the signal-to-noise ratio (SNR), precision, and accuracy of phase-contrast flow measurements at 3 T with the help of an in vitro model and to compare the results with data from two 1.5-T scanners. Materials and Methods:Using an identical setup of a laminar flow model and sequence parameters, measurements were done at one 3-T and at two 1.5-T systems. Precision, accuracy, and SNR were obtained for velocity encodings ranging from 55 up to 550 cm -1 . SNRs were calculated from the magnitude as… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
72
0
2

Year Published

2007
2007
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 85 publications
(79 citation statements)
references
References 27 publications
5
72
0
2
Order By: Relevance
“…Based on results from a previous study comparing PC-MRI at 1.5 T and 3 T, the 3-T system used on our study was expected to provide the same accuracy and precision compared to 1.5 T (27) and to show reduced noise levels in magnitude and velocity data relative to 1.5 T (27).…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…Based on results from a previous study comparing PC-MRI at 1.5 T and 3 T, the 3-T system used on our study was expected to provide the same accuracy and precision compared to 1.5 T (27) and to show reduced noise levels in magnitude and velocity data relative to 1.5 T (27).…”
Section: Discussionmentioning
confidence: 94%
“…Furthermore, as PC-MRA is sensitive to the available signal-to-noise ratio (SNR), contrast agents may help to enhance vessel surface extraction and 3D flow visualization (26)(27)(28).…”
Section: Contrast-enhanced (Ce) Mr Angiography (Mra) Is An Establishementioning
confidence: 99%
“…Imaging at 3T as performed in this study is associated with a gain of SNR (23), which is directly translated in reduced noise of the flow images. Yet, this generally accepted hypothesis will have to be evaluated in a setting where contrast-enhanced phase-contrast imaging in peripheral arteries is performed in larger numbers at 1.5 and 3T.…”
Section: Discussionmentioning
confidence: 99%
“…Several methods are available for this purpose -phase-contrast sequences quantify anterograde and retrograde flow volumes and velocities in any desired imaging plane, within a vessel or a valvular plane (89,90). The accuracy of phase-contrast measurements as assessed with in vitro models is excellent (91,92) and good correlations have been documented between CMR flow measurements and Doppler echocardiography (93), as well as cardiac catheterization (94,95). Cine imaging is applied to quantify the orifice of a stenotic valve (96).…”
Section: Valvular Heart Diseasementioning
confidence: 99%