In vivo bladder imaging with microelectromechanical-systems-based endoscopic spectral domain optical coherence tomography

Abstract: We report the recent technical improvements in our microelectromechanical systems (MEMS)-based spectral-domain endoscopic OCT (SDEOCT) and applications for in vivo bladder imaging diagnosis. With the technical advances in MEMS mirror fabrication and endoscopic light coupling methods, the new SDEOCT system is able to visualize morphological details of the urinary bladder with high image fidelity close to bench-top OCT (e.g., 10 mum12 mum axial/lateral resolutions, >108 dB dynamic range) at a fourfold to eightfo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
36
1
3

Year Published

2008
2008
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 51 publications
(40 citation statements)
references
References 44 publications
0
36
1
3
Order By: Relevance
“…Most reported systems acquire two-dimensional (2-D) circular cross-sectional images using a DC motor, microelectro-mechanical system (MEMS), or fiber optic rotary joint. 12,15,[23][24][25][26][27][28] To achieve 3-D imaging, a pullback mechanism along the probe can be added either manually or mechanically. [29][30][31][32] In colposcopic imaging, however, the OCT probe does not require flexibility and only needs a relative short probe length (around 10 cm).…”
Section: Introductionmentioning
confidence: 99%
“…Most reported systems acquire two-dimensional (2-D) circular cross-sectional images using a DC motor, microelectro-mechanical system (MEMS), or fiber optic rotary joint. 12,15,[23][24][25][26][27][28] To achieve 3-D imaging, a pullback mechanism along the probe can be added either manually or mechanically. [29][30][31][32] In colposcopic imaging, however, the OCT probe does not require flexibility and only needs a relative short probe length (around 10 cm).…”
Section: Introductionmentioning
confidence: 99%
“…X-ray computed tomography has been applied, but it is ionizing and not sensitive. Contrast-enhanced MRI has been applied, but it is expensive and bulky [1]. Although ultrasound (US) imaging is real-time, portable, relatively cost effective, and safe, conventional US imaging is not sensitive, especially, for imaging bladder cancers [2].…”
mentioning
confidence: 99%
“…With early systems, it has been shown that OCT has 100% sensitivity and 89% specificity for diagnosing transitional cell carcinoma based on differentiating its OCT appearance from inflammation and dysplasia [172]. Introduction of MEMS-based micro scanning mechanisms enabled further improvement of OCT probes, resulting in 4.5mm long scans at 8fps allowing for combining cross-sectional information with information about mucosal blood flow [173]. Using commercially available laparoscopic system, OCT was shown to be capable of staging tumors, including identifying muscle-invasive bladder tumors [174], reducing false-positive findings of fluorescence cystoscopy (Fig.…”
Section: Urinary Tractmentioning
confidence: 99%