2008
DOI: 10.1016/j.jbiomech.2008.04.021
|View full text |Cite
|
Sign up to set email alerts
|

In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities

Abstract: Analysis of polyethylene component wear and implant loosening in total knee arthroplasty (TKA) requires precise knowledge of in vivo articular motion and loading conditions. This study presents a simultaneous, in vivo measurement of tibiofemoral articular contact forces and contact kinematics in three TKA patients. These measurements were accomplished via a dual fluoroscopic imaging system and instrumented tibial implants during dynamic single leg lunge and chair risingsitting. The measured forces and contact … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

6
53
1

Year Published

2008
2008
2016
2016

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 85 publications
(60 citation statements)
references
References 30 publications
6
53
1
Order By: Relevance
“…We concluded in the manuscript that the accuracy in recreating dynamic motion might indeed decrease with increasing velocity. More recently the high accuracy of the dual fluoroscopic technique was validated using cadaveric knees and a robotic testing system for speeds up to 0.5 m/s and the technique was successfully applied to study of TKA kinematics during dynamic lunge and chair rising/sitting activities (Varadarajan et al, 2008). Without doubt, we agree that the restriction of motion analysis to activities performed at moderate velocity is a limitation of the system as clearly indicated in our paper.…”
supporting
confidence: 74%
See 2 more Smart Citations
“…We concluded in the manuscript that the accuracy in recreating dynamic motion might indeed decrease with increasing velocity. More recently the high accuracy of the dual fluoroscopic technique was validated using cadaveric knees and a robotic testing system for speeds up to 0.5 m/s and the technique was successfully applied to study of TKA kinematics during dynamic lunge and chair rising/sitting activities (Varadarajan et al, 2008). Without doubt, we agree that the restriction of motion analysis to activities performed at moderate velocity is a limitation of the system as clearly indicated in our paper.…”
supporting
confidence: 74%
“…This was also the primary objective of our paper. In this regard we would also like to direct readers to our recent study of dynamic weight-bearing activities following TKA (Varadarajan et al, 2008).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Previously reported knee forces and fluoroscopic kinematics measured during walking, stair ascent, dynamic single-leg lunge, and chair rising-sitting were used to evaluate the inverse finite element optimization algorithm [13,55,61]. From each implanted subject, 10 different force and kinematic vectors were selected.…”
Section: In Vivomentioning
confidence: 99%
“…Conventional bi-planar fluoroscopy cannot generally be used to measure patellofemoral kinematics after knee arthroplasty, although this method has been used to accurately measure the kinematics of the natural tibiofemoral (TF) and PF joints (Asano et al, 2001;Valstar et al, 2001;You et al, 2001;Kaptein et al, 2003;Varadarajan et al, 2008;Suggs et al, 2009). The challenge with the PF joint after arthroplasty is that the patellar component is only visible (and not even fully visible) in a projection that is sagittal or slightly deviated from the sagittal plane; otherwise it is obscured by the projection of the metal femoral component.…”
Section: Introductionmentioning
confidence: 99%