1998
DOI: 10.1583/1074-6218(1998)005<0359:ivcoaa>2.0.co;2
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Crushing of an Aortic Stent Enables Endovascular Repair of a Large Infrarenal Aortic Pseudoaneurysm

Abstract: Malpositioned stents that are hindering an endoluminal procedure may be crushed against the arterial wall in vivo to facilitate passage of endovascular instruments or devices.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
2

Year Published

2000
2000
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 11 publications
0
4
0
2
Order By: Relevance
“…There have been cases in the literature recently in which FAA was treated by an endovascularly placed graft. 59 We share the opinion that this method should be applied in treating complicated and high-risk cases, such as FAA at the aorta. 59 Using this method in cases of FAA in the groin, problems can be caused by kinking and thrombosis of the implanted stent graft.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…There have been cases in the literature recently in which FAA was treated by an endovascularly placed graft. 59 We share the opinion that this method should be applied in treating complicated and high-risk cases, such as FAA at the aorta. 59 Using this method in cases of FAA in the groin, problems can be caused by kinking and thrombosis of the implanted stent graft.…”
Section: Discussionmentioning
confidence: 95%
“…59 We share the opinion that this method should be applied in treating complicated and high-risk cases, such as FAA at the aorta. 59 Using this method in cases of FAA in the groin, problems can be caused by kinking and thrombosis of the implanted stent graft. It is hoped that very soon technology development will resolve this problem and provide a fast, safe, and less invasive procedure with better results.…”
Section: Discussionmentioning
confidence: 95%
“…Other than standard surgical approach, there have been cases in the literature recently in which FAA was treated by an endovascular placed graft [111]. Using this method in cases of FAA in the groin, problems can be caused by kinking and thrombosis of the implanted stent graft.…”
Section: Natural History and Treatmentmentioning
confidence: 99%
“…Ovaj postupak je primewen kod 32 naša bolesnika (36,8%), dok je kod 39 bolesnika (44,8%) posle resekcije pseudoaneurizme primewena bajpas-procedura. U posledwe vreme u literaturi se prikazuju i bolesnici kod kojih je anastomozna pseudoaneurizma lečena graftom postavqenim endovaskularno [65]. Za sada je reč o pojedinačnim slučajevima i sa kratkim periodom nadgledawa, pa je teško govoriti o pravoj vrednosti ovog metoda.…”
Section: Diskusijaunclassified