In vivo free‐breathing DTI and IVIM of the whole human heart using a real‐time slice‐followed SE‐EPI navigator‐based sequence: A reproducibility study in healthy volunteers

Abstract: The slice-following DWI SE-EPI sequence is a promising solution for clinical implementation, offering a robust improved workflow for further evaluation of DWI in cardiology. Magn Reson Med 76:70-82, 2016. © 2015 Wiley Periodicals, Inc.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

9
61
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 52 publications
(71 citation statements)
references
References 51 publications
(70 reference statements)
9
61
1
Order By: Relevance
“…Finally, the IVIM model is a nonlinear model of 2 diffusion compartments in which the relative weight of the pseudo‐diffusion compartment is about 1/10th of the dominant diffusion compartment. Echocardiographic data has revealed a volume fraction of blood in myocardium of 12.6% ± 1.8% healthy individuals at rest, which is confirmed by IVIM‐derived perfusion fractions of 12.2% ± 1.3% and 13.1 ± 6.00% . Accordingly, parameter fitting of low SNR data may lead to potential bias and variation because of the intrinsic model nonlinearity and the relatively weak contribution of the perfusion compartment to total signal attenuation.…”
Section: Introductionmentioning
confidence: 72%
See 3 more Smart Citations
“…Finally, the IVIM model is a nonlinear model of 2 diffusion compartments in which the relative weight of the pseudo‐diffusion compartment is about 1/10th of the dominant diffusion compartment. Echocardiographic data has revealed a volume fraction of blood in myocardium of 12.6% ± 1.8% healthy individuals at rest, which is confirmed by IVIM‐derived perfusion fractions of 12.2% ± 1.3% and 13.1 ± 6.00% . Accordingly, parameter fitting of low SNR data may lead to potential bias and variation because of the intrinsic model nonlinearity and the relatively weak contribution of the perfusion compartment to total signal attenuation.…”
Section: Introductionmentioning
confidence: 72%
“…An alternative to the IVIM tensor model is the IVPCM model, which parameterizes anisotropy with only 1 parameter (concentration of the von Mises distribution). Further investigations into IVIM can also consider the T 1 and T 2 relaxation effects to account for the different contributions of the compartments for different sequences and their respective timing parameters …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Arterial spin labelling (ASL) has been applied to the heart in experimental and clinical settings [13]. Also, intra voxel incoherent motion (IVIM) measurements have allowed assessing perfusion fractions without the use of contrast agents [1416]. However, both approaches provide limited contrast-to-noise ratios (CNR) compared to contrast-enhanced first-pass perfusion imaging and further research is required to translate these methods into clinical use.…”
Section: Introductionmentioning
confidence: 99%