2011
DOI: 10.1124/dmd.110.037358
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Magnetic Resonance Imaging to Detect Biliary Excretion of 19F-Labeled Drug in Mice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 6 publications
(13 citation statements)
references
References 16 publications
1
12
0
Order By: Relevance
“…Using this method, there is greater than 99% confidence that voxels containing bile acid analogue concentrations above 6.82 mM relative to the phantom are from actual 19 F signal, and not noise. This limit of detection was similar to that estimated for isoflurane [ 26 ]. We used liquid chromatography–mass spectrometry (LC–MS) to measure isoflurane in the gallbladder.…”
Section: Development Of 19 F-labeled Bile Acid Anasupporting
confidence: 86%
“…Using this method, there is greater than 99% confidence that voxels containing bile acid analogue concentrations above 6.82 mM relative to the phantom are from actual 19 F signal, and not noise. This limit of detection was similar to that estimated for isoflurane [ 26 ]. We used liquid chromatography–mass spectrometry (LC–MS) to measure isoflurane in the gallbladder.…”
Section: Development Of 19 F-labeled Bile Acid Anasupporting
confidence: 86%
“…Its octanol/water partition coefficient is 3.7 compared with chenodeoxycholic acid's partition coefficient of 23.3 (38). 19 F-MRI requires the imaging agent to be in solution, and we already calculated the limit of detection of a trifluorinated compound to be approximately 1 mM (13). Additionally, higher aqueous solubility reduces the passive permeability of the compound, allowing for a more specific analysis of active transporter function in enterohepatic circulation.…”
Section: Discussionmentioning
confidence: 99%
“…We determined the limit of detection of isoflurane by 19 F MRI imaging to be approximately 1 mM, equivalent to 3 mM total fluorine atoms (13). In the present report, our objectives were to synthesize a trifluorinated bile acid; characterize in vitro its affinity for bile acid transporters,stability and 19 F MRI signal; and measure its ability to concentrate in the murine gallbladder above the 19 F MRI limit of detection.…”
Section: Introductionmentioning
confidence: 99%
“…20 In the present work CA-lys-TFA, a novel bile acid analogue, was successfully and reproducibly imaged in the murine gallbladder using 19 F MRI. To our knowledge, this represents the first report that a drug absorbed orally can be imaged in vivo by 19 F MRI.…”
Section: Discussionmentioning
confidence: 90%