Abstract: Elastic and non-elastic bandages behave differently from one another, and non-elastic bandages not appearing to comply with medical recommendations concerning graduated pressure. There is a high level of variability between subjects for some compression bandages (non-elastic and figure-of-eight methods).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
29
0
3

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(33 citation statements)
references
References 24 publications
1
29
0
3
Order By: Relevance
“…However, as the aim of this previous study was to compare the pressure applied by different application techniques, it was carried out for a single bandage type. Other studies were focused on the influence of bandage mechanical properties and position (supine, standing, sitting) on the interface pressure, 3,8,11,26 but as far as we know, none of them measured the stretch of the applied bandage, though it is one of the main parameters which controls the interface pressure.…”
Section: Introductionmentioning
confidence: 99%
“…However, as the aim of this previous study was to compare the pressure applied by different application techniques, it was carried out for a single bandage type. Other studies were focused on the influence of bandage mechanical properties and position (supine, standing, sitting) on the interface pressure, 3,8,11,26 but as far as we know, none of them measured the stretch of the applied bandage, though it is one of the main parameters which controls the interface pressure.…”
Section: Introductionmentioning
confidence: 99%
“…The PicoPress system is a portable digital gauge specially designed to measure the pressure exerted by a bandage. Its reliability and reproducibility have already been demonstrated, and it is known as one of the best systems for measuring interface pressure .…”
Section: Discussionmentioning
confidence: 99%
“…A transducer pad was placed about 12 cm above the inner ankle at the medial aspect of the lower leg, where the tendon changes into the muscular part of the gastrocnemius muscle. This point is known as the B1 point according to a previous report . The volunteer was placed in the supine position, and the bandage pressure during inactivity (the resting pressure) was measured.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations