2016
DOI: 10.1016/j.ejmp.2016.10.022
|View full text |Cite
|
Sign up to set email alerts
|

In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 40 publications
1
16
0
Order By: Relevance
“…(2016). 28 This dose level was quite tolerable for skin tissue, but the tissue at the exposed site would require time to repair and recover from the daily radiation injury. This study was limited by the small sample size and the lack of in vivo skin dose measurements in EBRT.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…(2016). 28 This dose level was quite tolerable for skin tissue, but the tissue at the exposed site would require time to repair and recover from the daily radiation injury. This study was limited by the small sample size and the lack of in vivo skin dose measurements in EBRT.…”
Section: Discussionmentioning
confidence: 99%
“…The EBRT dose was obtainable only from the treatment planning system, which might be inaccurate for superficial skin dose estimation due to the limitation of the pencil beam convolution dose calculation algorithm. 28 , 29 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The majority of studies confirm that non-ionization and non-invasive methods with cell-therapy would affect skin tissue injury. Radiation-induced skin tissue injury, as the most common side effect of radiotherapy methods, interventional radiation therapy, and nuclear events, is being increased with new methods 1 . Reports indicate that ~ 95% of people who receive radiation therapy have experienced acute or chronic skin tissue radiation side effects 2 .…”
Section: Introductionmentioning
confidence: 99%
“…In many applications, it is desired to have a distributed network of miniaturized, solid-state dosimeters that combine a compact, low-power electronic readout and a small and robust design to achieve a spatial map of the deposited dose. In medical scenarios, where radiation doses on human skin or in human organs have to be assessed, flexibility and high integration density of the sensor array are further crucial properties ( 6 , 7 ). Moreover, the possibility of wireless communication would allow the facile integration of a network of sensors over large areas to monitor or detect radiation contamination sources.…”