2004
DOI: 10.1002/mrm.20181
|View full text |Cite
|
Sign up to set email alerts
|

In vivo study of microbubbles as an MR susceptibility contrast agent

Abstract: The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison®, was studied with rat liver imaging at 7 T. Optison® suspension in two different doses (0.15 mL/kg and 0.4 mL/kg) was injected into rats, and induced transverse relaxation rate increases (⌬R 2 *) of 29.1 ؎ 1.6 s -1 (N ‫؍‬ 2) and 61.5 ؎ 12.9 s -1 (N ‫؍‬ 6), respectively, in live… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
31
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(34 citation statements)
references
References 26 publications
3
31
0
Order By: Relevance
“…Time constants of the decay obtained from monoexponentialˆts were 39 s for 125 mg W mL; 50 for 100 mg W mL; 51 for 76 mg W mL; and 57 for 67 mg W mL. Because R2 * was considered to be proportional to the microbubble volume fraction, [5][6][7] the microbubble concentration was exponentially decreased over time in the syringe phantom. Figure 2 shows the …”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Time constants of the decay obtained from monoexponentialˆts were 39 s for 125 mg W mL; 50 for 100 mg W mL; 51 for 76 mg W mL; and 57 for 67 mg W mL. Because R2 * was considered to be proportional to the microbubble volume fraction, [5][6][7] the microbubble concentration was exponentially decreased over time in the syringe phantom. Figure 2 shows the …”
Section: Resultsmentioning
confidence: 99%
“…7,11,14 This implies that a high magneticˆeld is necessary to measure such weak susceptibility. Thus, previous studies 3,5,6 could be conducted at advantageous high magneticˆelds (2T or greater). Although the availability of high-ˆeld MR systems has increased, in most hospitals, magnetiĉ elds of MR scanners do not exceed 3T.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The first in vivo investigation of susceptibility contrast induced by MBs was reported in liver using Optison Ò , MBs with human albumin shell with perfluorocarbon as core gas, at 7 T in rat liver (Wong et al 2004). Moreover, a peculiarity of the albumincoated MBs is the ability to adhere only to the vessel walls in the setting of endothelial dysfunction and not to normally functioning endothelium, thus suggesting also the use of these MBs as markers of endothelial integrity (Villanueva et al 1997).…”
Section: Introductionmentioning
confidence: 98%