Incidence and Risk Factors of Hemolysis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
27
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(28 citation statements)
references
References 22 publications
0
27
0
1
Order By: Relevance
“…This will allow us to identify, for example, the most important risk factors of hemolysis after a TAVI procedure. The recent study by Laflamme et al 19 identifies wall shear rate 9 and the energy loss index 27 as risk factors in patient with severe prosthesispatient mismatch. Numerical simulations have the theoretical advantage over experimental studies for the investigation of TAVR to overcome the limit of the spatial resolution, 2,35 which makes the evaluation of many in vivo flow and structural characteristics very difficult.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…This will allow us to identify, for example, the most important risk factors of hemolysis after a TAVI procedure. The recent study by Laflamme et al 19 identifies wall shear rate 9 and the energy loss index 27 as risk factors in patient with severe prosthesispatient mismatch. Numerical simulations have the theoretical advantage over experimental studies for the investigation of TAVR to overcome the limit of the spatial resolution, 2,35 which makes the evaluation of many in vivo flow and structural characteristics very difficult.…”
Section: Discussionmentioning
confidence: 98%
“…Like in other cardiovascular fields, in silico models have been applied to better understand the mechanics and hemodymanics of devices and treated vessels; in the aortic root pathologies they are emerging as useful tools for the prediction and the interpretation of the phenomena involved and for the design optimization to increase durability and reduce several risk factors such as obstruction of coronary arteries, valve regurgitation 34 and hemolyis. 19 The behavior of a percutaneous valve is influenced either by the mechanics of the aortic root, the leaflets and the stent frame as well as the fluid passing through the site where the valve is implanted. Experimental studies for the investigation of TAVR have a low spatial resolution 2,35 and many flow and structural characteristics either cannot be evaluated, or can only be evaluated with difficulty.…”
Section: Introductionmentioning
confidence: 99%
“…8), vortex generation and the presence of recirculation areas. In addition, the determination of shear stresses is very important as a risk factor for hemolysis (Laflamme et al, 2015).
Fig.
…”
Section: Discussionmentioning
confidence: 99%
“…Laflamme et al reported incidence of hemolysis after TAVI at 14.8%, but no patient required transfusion. 27 There has been no report assessing the clinical impact of hemolysis after TAVI.…”
Section: Percutaneous Closure As a Treatment Option For Paravalvular mentioning
confidence: 99%