2011
DOI: 10.2967/jnumed.111.088328
|View full text |Cite
|
Sign up to set email alerts
|

Incidence of Increased 68Ga-DOTANOC Uptake in the Pancreatic Head in a Large Series of Extrapancreatic NET Patients Studied with Sequential PET/CT

Abstract: The aim of our retrospective study was to assess the incidence of increased uptake of 68 Ga-DOTANOC in the head of the pancreas among a large population of patients with extrapancreatic neuroendocrine tumors studied with serial 68 Ga-DOTANOC PET/CT. Methods: Patients who had undergone at least two 68 Ga-DOTANOC PET/CT studies over time were included. Uptake in the head of the pancreas was measured and compared with uptake in normal liver parenchyma (target-to-liver ratio). Patients were followed up for 6-24 mo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
39
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 61 publications
(44 citation statements)
references
References 19 publications
4
39
1
Order By: Relevance
“…Both tracers showed false-positive results in the pancreas (uncinate process) of 2 patients. This falsepositive finding has been described before (35). There was 1 further false-positive result with 68 Ga-DOTATATE in the prostate.…”
Section: Discussionmentioning
confidence: 54%
“…Both tracers showed false-positive results in the pancreas (uncinate process) of 2 patients. This falsepositive finding has been described before (35). There was 1 further false-positive result with 68 Ga-DOTATATE in the prostate.…”
Section: Discussionmentioning
confidence: 54%
“…The CT attenuation correction acquisition parameters were 120 kV voltage, 30 mA tube current and 5 mm slice thickness. In centre B images were acquired according to a previously described protocol [17]. In particular, PET/CT was performed on a dedicated hybrid scanner (Discovery STE or Discovery LS; GE Healthcare, Chalfont St. Giles, UK).…”
Section: Patientsmentioning
confidence: 99%
“…Prior to PET/ CT acquisition the patients were hydrated with 500 ml of water. 18 DOTANOC was labelled with 68 Ga according to a previously described protocol [17]. The administered dose of 68 Ga-DOTANOC was 1.5-2 MBq/kg, and the uptake time was 50-70 min after tracer injection.…”
Section: Patientsmentioning
confidence: 99%
“…However, considering the physiological uptake of 68 Ga-DOTA-peptides at the head of the pancreas [34,35], positive findings in this area should be interpreted carefully. In our population, the suspicion of pancreatic nodules raised by CT was confirmed in almost half of the cases both at the head and the body/tail level.…”
Section: Discussionmentioning
confidence: 97%