2011
DOI: 10.1016/j.amjcard.2010.10.054
|View full text |Cite
|
Sign up to set email alerts
|

Incidence, Predictors, and Outcome of Conduction Disorders After Transcatheter Self-Expandable Aortic Valve Implantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

18
130
4
1

Year Published

2011
2011
2015
2015

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 164 publications
(153 citation statements)
references
References 16 publications
18
130
4
1
Order By: Relevance
“…The evolution of conduction disorders took place over a period of 7 days after implantation. In our series, complete atrioventricular block was seen in 13.3%, while 8.9% suffered from type II second-degree atrioventricular block; thus, 22.2% of the patients developed an indication for permanent pacemaker implantation corroborating previous findings (27)(28)(29)(35)(36)(37)(38)(39). Their intracardiac measurements revealed that the occurrence of first-degree atrioventricular block was predominantly due to the prolongation of HV interval, which might be prognostically relevant (40).…”
Section: Conduction Disorderssupporting
confidence: 77%
“…The evolution of conduction disorders took place over a period of 7 days after implantation. In our series, complete atrioventricular block was seen in 13.3%, while 8.9% suffered from type II second-degree atrioventricular block; thus, 22.2% of the patients developed an indication for permanent pacemaker implantation corroborating previous findings (27)(28)(29)(35)(36)(37)(38)(39). Their intracardiac measurements revealed that the occurrence of first-degree atrioventricular block was predominantly due to the prolongation of HV interval, which might be prognostically relevant (40).…”
Section: Conduction Disorderssupporting
confidence: 77%
“…18 Despite recent evidence of the association between conduction disturbances and baseline ECG and procedural parameters, such as LBBB with left axis deviation and inter-ventricular septum >17 mm, RBBB and paroxysmal AVB episodes during the procedure, preoperative bradycardia, over-sizing prosthesis, a confirmatory multivariate analysis was not performed in the present study due to the limited sample size. [13][14][15][16][17][18][19][20][21] Moreover, the finding that first grade AVB and QRS width increased more in patients approached by CV confirms previous reports that the self-expandable characteristic of this prosthesis may have a greater effect on the nearby electrical structures. 9,13,16,17,18 Compared to its own baseline the ES-TA surprisingly reported higher rate of post-procedural LBBB compared to the other two groups.…”
supporting
confidence: 77%
“…1,2 Following TAVI, electrical conduction abnormalities are known to occur, [3][4][5][6][7][8][9][10][11][12][13][14][15][16] leading to the placement of a permanent pacemaker (PM) in 5-46% of cases [17][18][19][20][21] .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The atrioventricular block is a complication often described, and may reach one third of patients, especially with CoreValve [19]. Balloon-expandable prostheses, such as the Edwards Sapien and Inovare, had rates of need for permanent cardiac pacing at about 4.5% [7].…”
Section: Discussionmentioning
confidence: 99%