Incorrect Performance of the Breath Hold Method in the Old Underestimates Cerebrovascular Reactivity and Goes Unnoticed Without Concomitant Blood Pressure and End-Tidal CO2 Registration

Abstract: The number of inaccurate breath holds was unacceptably high, moreover, these could not be identified from CBFV registrations alone. Therefore, reports of CR based on breath holds in older subjects without coregistration of BP and either end-tidal CO(2) or chest-expansion should no longer be acceptable.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
19
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 35 publications
1
19
0
Order By: Relevance
“…Oxygenation of the frontal cortex was measured using the validated technique of NIRS (Smielewski et al 1995;Brady et al 2007). Changes in the concentration of oxygenated and deoxygenated haemoglobin (O 2 Hb and HHb, respectively) in the cerebral cortex were measured (Mehagnoul-Schipper et al 2000;van Beek et al 2012). The basic principle of NIRS is that near-infrared light penetrates the skull and brain and is absorbed by the chromophores O 2 Hb and HHb, which have different absorption spectra.…”
Section: Instrumentationmentioning
confidence: 99%
See 4 more Smart Citations
“…Oxygenation of the frontal cortex was measured using the validated technique of NIRS (Smielewski et al 1995;Brady et al 2007). Changes in the concentration of oxygenated and deoxygenated haemoglobin (O 2 Hb and HHb, respectively) in the cerebral cortex were measured (Mehagnoul-Schipper et al 2000;van Beek et al 2012). The basic principle of NIRS is that near-infrared light penetrates the skull and brain and is absorbed by the chromophores O 2 Hb and HHb, which have different absorption spectra.…”
Section: Instrumentationmentioning
confidence: 99%
“…This data segmentation is based on a trade-off between a reduction in spectral variance and keeping sufficient spectral resolution. Each Hanning-windowed segment was fast Fourier transformed and the periodograms were averaged to calculate the autospectrum of MAP, CBFV and O 2 Hb (Zhang et al 1998;van Beek et al 2012). The spectral power of oscillations was calculated as the area under the curve of the power spectrum density plots.…”
Section: Data Processingmentioning
confidence: 99%
See 3 more Smart Citations