Abstract:In the text describing the casting properties of some new steels, on page 386, line 43, the liquidus temperature (~C) for steel 10Khl8N9TL should be 1440 instead of 1140.In Fig. 2, on page 388, the caption should read -Impeller of 06Khl3N4MBL steel after pr~tuction tests in highly minerafized chloride water with abrasive particles (absence of hydrogen sulfide).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.