Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Molecular fluorescence-guided surgery has shown promise for tumor margin delineation but is limited by its depth profiling capability. Interestingly, most fluorophores, either clinically approved or in clinical trials, can also be used as photoacoustic contrast agents, yet their use is limited due to the low light fluence permitted for clinical use and the limited sensitivity of current photoacoustic imaging systems. There is therefore an urgent unmet need to establish methods for enhancing contrast in molecular targeted PA imaging which could potentially complement and overcome limitations in molecular fluorescence guided therapies. In this study, we compare the photoacoustic (PA) and fluorescence imaging capabilities of a cetuximab-IRDye800 conjugate in a subcutaneous tumor xenograft model. We demonstrate that while the fluorescence signal increases steadily over time after administration of cetuximab-IRDye800, PA signal peaks early (~2 fold higher at 6-hour as compared to pre-injection controls) and then decreases (~1.3 fold higher at 24-hour as compared to pre-injection controls). This pattern aligns with previous findings using other antibody-conjugated PA contrast agents. Mechanistically, we demonstrate that the formation of H-aggregates upon antibody conjugation enhances PA contrast of the IRDye800. The disruption of these H-aggregates, as the antibody-dye conjugate is degraded post receptor-mediated endocytosis, decreases PA signal intensity. The timeframe of maximum PA signal and decrease thereafter is consistent with the time frame of receptor-mediated endocytosis of cetuximab-IRDye800. Our data suggests that tumor cell surface binding results in peak PA signal while lysosomal localization and degradation results in a significant drop in PA signal. Our study sheds light on the distinct temporal dynamics of PA and fluorescence signals of Cetuximab-IRDye800 conjugate and we propose that optimizing IRDye800 conjugation to antibodies can further enhance PA signal intensity when timed to precisely to capture IRDye800 in an H-aggregate form.
Molecular fluorescence-guided surgery has shown promise for tumor margin delineation but is limited by its depth profiling capability. Interestingly, most fluorophores, either clinically approved or in clinical trials, can also be used as photoacoustic contrast agents, yet their use is limited due to the low light fluence permitted for clinical use and the limited sensitivity of current photoacoustic imaging systems. There is therefore an urgent unmet need to establish methods for enhancing contrast in molecular targeted PA imaging which could potentially complement and overcome limitations in molecular fluorescence guided therapies. In this study, we compare the photoacoustic (PA) and fluorescence imaging capabilities of a cetuximab-IRDye800 conjugate in a subcutaneous tumor xenograft model. We demonstrate that while the fluorescence signal increases steadily over time after administration of cetuximab-IRDye800, PA signal peaks early (~2 fold higher at 6-hour as compared to pre-injection controls) and then decreases (~1.3 fold higher at 24-hour as compared to pre-injection controls). This pattern aligns with previous findings using other antibody-conjugated PA contrast agents. Mechanistically, we demonstrate that the formation of H-aggregates upon antibody conjugation enhances PA contrast of the IRDye800. The disruption of these H-aggregates, as the antibody-dye conjugate is degraded post receptor-mediated endocytosis, decreases PA signal intensity. The timeframe of maximum PA signal and decrease thereafter is consistent with the time frame of receptor-mediated endocytosis of cetuximab-IRDye800. Our data suggests that tumor cell surface binding results in peak PA signal while lysosomal localization and degradation results in a significant drop in PA signal. Our study sheds light on the distinct temporal dynamics of PA and fluorescence signals of Cetuximab-IRDye800 conjugate and we propose that optimizing IRDye800 conjugation to antibodies can further enhance PA signal intensity when timed to precisely to capture IRDye800 in an H-aggregate form.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.