2019
DOI: 10.1002/cphc.201900075
|View full text |Cite
|
Sign up to set email alerts
|

Incubation Effect of Pre‐Irradiation on Bubble Formation and Ablation in Laser Ablation in Liquids

Abstract: Pulsed laser ablation in liquids (PLAL) is a multi‐scale process, which is widely studied either in batch ablation with prolonged target irradiation as well as mechanistic investigations, in a defined (single‐shot) process. However, fundamental studies on defined pulse series are rare. We have investigated the effect of a developing rough morphology of the target surface on the PLAL process with nanosecond pulses and, partially, picosecond pulses. At low fluence the cavitation bubble growth as well as the abla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 17 publications
(17 citation statements)
references
References 44 publications
0
17
0
Order By: Relevance
“…4. Factors such as the increase in pressure caused by the formation of the cavitation bubble 40,41 , changes in the optical force gradient 22 , and the surrounding medium can affect the bubble formation 42 . Differences in individual laser powers as well as the spatial and temporal overlap of the two pulses can change the profile of the force gradient of the optical trap and affect the heating of the bubble.…”
Section: Discussionmentioning
confidence: 99%
“…4. Factors such as the increase in pressure caused by the formation of the cavitation bubble 40,41 , changes in the optical force gradient 22 , and the surrounding medium can affect the bubble formation 42 . Differences in individual laser powers as well as the spatial and temporal overlap of the two pulses can change the profile of the force gradient of the optical trap and affect the heating of the bubble.…”
Section: Discussionmentioning
confidence: 99%
“…By integrating the mass density over the whole bubble area we derive a mass of 2.2 × 10 −7 g, corresponding to a volume of ablated zinc of ≤1 μm depth at a presumed crater area of 0.04 mm 2 . The derived ablation depth is much larger than the laser absorption length in zinc and probably caused by 2 effects: corrugation of the surface during the ablation with several pulses per unit area 49 and a heat-affected zone that is considerable larger than the absorption length due to fast heat conduction by phonons and fast electrons. 68 While the total mass can be deduced from the absorption step height, the spectrum close to the edge can yield information about the ablated species.…”
Section: X-ray Spectroscopymentioning
confidence: 86%
“…The zinc wire (supported by the back wall) 48 is pulled through the chamber at a speed that replaces the irradiated spot within around 5 laser pulses in order to optimize the ablation efficiency. 49…”
Section: Ablation Chambermentioning
confidence: 99%
See 2 more Smart Citations