Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
48
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 68 publications
(51 citation statements)
references
References 14 publications
2
48
0
1
Order By: Relevance
“…This may allow early detection of device and lead malfunction. [7][8][9][10][11] Thus, the routine use of RPM enhances device safety and resource use and may improve clinical outcomes.…”
mentioning
confidence: 99%
“…This may allow early detection of device and lead malfunction. [7][8][9][10][11] Thus, the routine use of RPM enhances device safety and resource use and may improve clinical outcomes.…”
mentioning
confidence: 99%
“…Some engineering considerations predict that inside-out abrasions should occur less frequently in 7F leads than 8F leads because the conductor lumens are narrower and closer to the central axis. 17 This is supported by a prospective study in which exteriorized cables were more common in 8F leads than 7F leads (17.9% versus 9.4% for leads implanted <6 years). However, variation in reported rates may be caused by lack of standardized imaging and uniform definitions.…”
Section: Riata-family Insulation Breachesmentioning
confidence: 79%
“…17,19 Abnormally low impedance may also be caused by reversed connection of proximal and distal shock coils to the header on IS-1 leads.…”
Section: High-voltage Insulation Breachesmentioning
confidence: 99%
See 1 more Smart Citation
“…Data from a large cross sectional study from Canada surveying 4,358 leads revealed an overall 4.6% rate of electrical abnormalities, most common being elevated pacing thresholds and pacing lead impedance [16]. A multicenter study by Abdelhadi et al [17] also found higher electrical failure in 27% of the externalized lead cohort, suggesting leads with externalization are more likely to have electrical malfunction. These findings likely suggest that leads with externalization will likely manifest some form of electrical malfunction over time and as such require very close monitoring of electrical parameters and should prompt appropriate action, if significant electrical defects are detected.…”
Section: Discussionmentioning
confidence: 99%