2018
DOI: 10.1615/plasmamed.2018028140
|View full text |Cite
|
Sign up to set email alerts
|

Indirect Inactivation of Candida guilliermondii by Using a Plasma Synthetic Jet Actuator: Effect of Advected Charged Particles

Abstract: Plasma synthetic jet actuators (PSJAs) demonstrated their ability to produce a Candida guilliermondii, the passage of charges and their migration toward the sample can either be allowed or prevented log colony-forming unit (CFU) reduction were observed for agar substrate and saline solution, respectively, at the highest energy dose treatment with the grid grounded. Under the same condi-1 log CFU. In addition to biological tests, chemical analyses have been carried out to identify the C. guilliermondii, both on… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 15 publications
0
7
1
Order By: Relevance
“…When the wire mesh is grounded (red line), about 95% of the charges inside the flow are conveyed by means of the mesh to ground, severely limiting the number of charge particles reaching the target surface. Unlike what was previously seen in Neretti et al, [ 22 ] in Actuator 2, the distribution of the surface potential increases by the 25% when the mesh is left floating, compared with the potential measured without mesh. A possible explanation for this increment is a different fluid‐dynamic regime for the two conditions.…”
Section: Resultscontrasting
confidence: 69%
See 4 more Smart Citations
“…When the wire mesh is grounded (red line), about 95% of the charges inside the flow are conveyed by means of the mesh to ground, severely limiting the number of charge particles reaching the target surface. Unlike what was previously seen in Neretti et al, [ 22 ] in Actuator 2, the distribution of the surface potential increases by the 25% when the mesh is left floating, compared with the potential measured without mesh. A possible explanation for this increment is a different fluid‐dynamic regime for the two conditions.…”
Section: Resultscontrasting
confidence: 69%
“…Hence, the distance between the plasma end and the target is about 20 mm. The same distance was used to obtain the results reported in the investigation described in Neretti et al [ 22 ] where Actuator 3 (annular geometry) was tested.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations