2020
DOI: 10.1109/tec.2020.2972500
|View full text |Cite
|
Sign up to set email alerts
|

Indirect Torque Control of a Cascaded Brushless Doubly-Fed Induction Generator Operating With Unbalanced Power Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…The derived CW voltage equations, namely (20) and (21), are the object model using to design CW(MSC) current controller thereafter. It should be noted that ( 20) and ( 21) include all of the cross-coupling terms and disturbances on d-axis and q-axis whereas the existing proposed models in literature [15]- [17] neglected all or most of the cross-coupling terms and disturbances. Therefore, the derived model expressed as (20) and (21) in this paper gives a much more accurate analytical model for BDFIG (MSC) current control under grid voltage unbalance.…”
Section: A Vector Model Of Bdfig (Msc) Under Grid Voltage Unbalancementioning
confidence: 99%
See 3 more Smart Citations
“…The derived CW voltage equations, namely (20) and (21), are the object model using to design CW(MSC) current controller thereafter. It should be noted that ( 20) and ( 21) include all of the cross-coupling terms and disturbances on d-axis and q-axis whereas the existing proposed models in literature [15]- [17] neglected all or most of the cross-coupling terms and disturbances. Therefore, the derived model expressed as (20) and (21) in this paper gives a much more accurate analytical model for BDFIG (MSC) current control under grid voltage unbalance.…”
Section: A Vector Model Of Bdfig (Msc) Under Grid Voltage Unbalancementioning
confidence: 99%
“…6(a). Compared to existing control methods in [15]- [17], its improvements are as follows: Firstly, a single current closed-loop controller without the CW flux, PW flux or RW current estimations is designed. Thus, it is much more simple and applicable and has better parameter robustness.…”
Section: B Current Controller Designmentioning
confidence: 99%
See 2 more Smart Citations
“…BDFTSIG applications have recently witnessed booming interest especially in the past 10 years [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22]. A high performance vector control based technique was elaborated showing acceptable performance yet at the penalty of less tolerance to machine parameters' variation [7].…”
Section: Introductionmentioning
confidence: 99%