2012
DOI: 10.1007/s10877-012-9423-4
|View full text |Cite
|
Sign up to set email alerts
|

Indocyanine green dye administration can cause oxygen desaturation

Abstract: Indocyanine green (ICG) video-angiography is used intraoperatively to visualize the vascular integrity during neurovascular surgical procedures [1]. Oxygen desaturation following ICG injection has not been described previously nor is it mentioned in the list of adverse effects of the dye by the manufacturer.We report here a 42-year-old female who underwent clipping of the basilar artery aneurysm. The ICG dye (Aurogreen TM , Aurolab, Madurai, India) was injected at the recommended dose of 0.25 mg/kg before clip… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…[ 26 ] However, ICG can cause transient oxygen desaturation. [ 27 ] IMD use confirms aneurysm isolation and patency of parent vessel and branching arteries. Hui et al .…”
Section: Methodsmentioning
confidence: 89%
“…[ 26 ] However, ICG can cause transient oxygen desaturation. [ 27 ] IMD use confirms aneurysm isolation and patency of parent vessel and branching arteries. Hui et al .…”
Section: Methodsmentioning
confidence: 89%
“…6 All ICG angiographic images were acquired in the arterial phase to ensure consistency in measurements. After intravenous ICG injection, the sound of the saturation monitor changed after 50 to 70 seconds of dwell time, which is when the oximetry desaturation occurs because of the ICG 15 or when ICG is believed to enter the systemic circulation during imaging. The contralateral flap perfusion was marked from the midline of the flap, and a photograph was taken using a digital camera and a scale.…”
Section: Methodsmentioning
confidence: 99%
“…The phenomenon was first described in humans as an anecdotal report in 2013. 8,9 Furthermore, inaccuracy in pulse oximetry measurement has been attributed to interference by several intravenous dyes including methylene blue, ICG, and indigo carmine, as well as placement over dark nail polish and under fluorescent and xenon arc surgical lamps. 10 Here, we present the first posited mechanism of artificial desaturation in children undergoing transpupillary thermotherapy using ICG for the treatment of retinoblastoma.…”
Section: Proposed Mechanismmentioning
confidence: 99%