2021
DOI: 10.1177/01945998211000432
|View full text |Cite
|
Sign up to set email alerts
|

Indocyanine Green Fluorescence Angiography of the Transverse Cervical Arterial Supply to Clavicle Flaps: An Anatomical Study

Abstract: Objective To describe the anatomy of the transverse cervical artery and to prove its perfusion to the clavicle using indocyanine green fluorescence angiography as an alternative vascularized bone for head and neck reconstruction. Study Design Cadaveric dissection. Setting Anatomy lab. Methods Twenty-two necks and shoulders from 11 fresh-frozen cadavers were dissected. The transverse cervical artery diameter, length, emerging point, and the length of clavicle segment harvested were described. Photographic and n… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 40 publications
0
4
0
Order By: Relevance
“…Using indocyanine green in the study of breast vascularization could provide information on breast vascularization, without interfering with or altering the anatomy or deep vascularization. [23,24].…”
Section: Discussionmentioning
confidence: 99%
“…Using indocyanine green in the study of breast vascularization could provide information on breast vascularization, without interfering with or altering the anatomy or deep vascularization. [23,24].…”
Section: Discussionmentioning
confidence: 99%
“…In cadaveric studies the feasibility of ICG to penetrate cancellous (endosteal) portion of bone through penetrating periosteal capillaries has been shown [21][22][23]. NIRF with ICG should therefore allow adequate assessment of bone perfusion.…”
Section: Discussionmentioning
confidence: 99%
“…These networks are connected through small capillaries. This intricate network allows sustained bone perfusion even when the nutrient artery providing the endosteal perfusion is lost, injured or not included in a bone flap [23,28]. With this model Gitajn et al (2020) and Elliot et al (2019) extrapolated several parameters and concluded that a combination of LBP and LPF values had a 90% sensitivity, 88% specificity and 89% accuracy in diagnosing injured porcine bone.…”
Section: Discussionmentioning
confidence: 99%
“…To verify the cuboid blood supply, we used a widespread procedure consisting of injecting ICG to perform a fluorescence angiography. 16 The proximal cut end of the DPA was cannulated with a 24-gauge plastic tip peripheral venous catheter. The flap was irrigated with warm saline to repair any leakage.…”
Section: Methodsmentioning
confidence: 99%