2009
DOI: 10.1016/j.jenvman.2007.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Indoor air quality investigation according to age of the school buildings in Korea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
106
6
3

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 174 publications
(122 citation statements)
references
References 16 publications
7
106
6
3
Order By: Relevance
“…So the possibility of raised levels of TVOCs in newly dwellings is more as compared with that of old buildings. This finding of current study comes in agreement to previous studies [21]- [22]. The averaged concentrations of TVOCs recorded for this study were also higher in new building as compared with old one.…”
Section: A Evaluation Of Indoor Air Quality For Averaging Period Of supporting
confidence: 93%
“…So the possibility of raised levels of TVOCs in newly dwellings is more as compared with that of old buildings. This finding of current study comes in agreement to previous studies [21]- [22]. The averaged concentrations of TVOCs recorded for this study were also higher in new building as compared with old one.…”
Section: A Evaluation Of Indoor Air Quality For Averaging Period Of supporting
confidence: 93%
“…The TVOC concentrations measured in this study were either at similar or higher than the studies performed in schools in other countries: in Sweden (mean TVOC of 6 g/m 3 by Smedje et al, 1997), in Minnesota, USA (median TVOC of 14 g/m 3 by Adgate et al, 2004), in Australia (max TVOC of 94 g/m 3 by Zhang et al, 2006), and in Michigan, USA (mean TVOC of 58 g/m 3 by Godwin and Batterman, 2007), but lower than those measured in South Korea (mean TVOC of 374 g/m 3 by Yang et al, 2009). However, one should note that different definitions of TVOC were used, e.g., TVOC 10 (Zhang et al, 2006) and sum of the both target and non-target peaks normalized to toluene equivalents (Godwin and Batterman, 2007).…”
Section: Classroommentioning
confidence: 88%
“…The concentration range was reported as 6-11 g/m 3 for Dutch kindergartens (Kotzias, 2005). Formaldehyde concentrations measured in Korean kindergartens (Yang et al, 2009) were higher with a mean value of 195 g/m 3 (range: 45-690 g/m 3 ). The overall average of the concentrations measured in this study (85 g/m 3 ) was clearly higher than the Dutch, and in the range of the Danish and Korean kindergartens.…”
Section: Kindergartenmentioning
confidence: 92%
See 1 more Smart Citation
“…Currently, considerable efforts have been made worldwide to clarify the effects of indoor air quality on human health (Yang et al, 2009;Hasheminassab et al, 2014;Zhu et al, 2015). People spend most of their times indoors (Lai et al, 2004;Tiwari et al, 2015); thus, indoor air pollutants, even at low concentrations, may have a considerable effect on human health due to the long exposure periods (Simoni et al, 2003).…”
Section: Introductionmentioning
confidence: 99%