2013
DOI: 10.3928/1081597x-20130318-06
|View full text |Cite
|
Sign up to set email alerts
|

Inferior Intrastromal Corneal Ring Segments in Paracentral Keratoconus With No Coincident Topographic and Coma Axis

Abstract: One Ferrara-type ICRS of 150° of arc with a thickness of 150, 200, or 250 μm implanted inferiorly may reduce both astigmatism and corneal coma-like aberrations in keratoconic eyes with no coincident topographic and comatic axes, providing an improvement of UDVA and CDVA values.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
57
0
3

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 48 publications
(65 citation statements)
references
References 16 publications
5
57
0
3
Order By: Relevance
“…The ICRSs were implanted following the nomogram used in previous studies. [18][19][20][21] Two experienced surgeons performed all implantation procedures (J.F.A., C.L.) using a femtosecond laser, and using the procedure described in previous studies.…”
Section: Methodsmentioning
confidence: 99%
“…The ICRSs were implanted following the nomogram used in previous studies. [18][19][20][21] Two experienced surgeons performed all implantation procedures (J.F.A., C.L.) using a femtosecond laser, and using the procedure described in previous studies.…”
Section: Methodsmentioning
confidence: 99%
“…ntrastromal corneal ring segments (ICRS) implantation is a surgical procedure used for the treatment of keratoconus, enabling both a therapeutic and refractive improvement. [1][2][3] Both the safety and the refractive efficacy of the implant depend on the correct selection of the implant features and a precise intrastromal surgical implantation. Shallower intrastromal tunnels are associated with complications such as implant exposure due to corneal thinning over the implant, segment migration and extrusion, astigmatism overcorrection, or corneal melting.…”
Section: O R I G I N a L A R T I C L Ementioning
confidence: 99%
“…Чем больше граней у имплантата, тем больше преломление при попадании на них световых лучей. Например, сегменты Keraring способствуют снижению аберраций высшего порядка (вертикальной и горизонтальной комы), тогда как после имплантации сегментов Intacs, напротив, наблюдается появление новых аберраций, особенно отрицательной сферической аберрации и комы, что объясняется тем, что сегменты Keraring имеют треугольную форму на поперечном срезе, сегменты Intacsгексагональную [14][15][16][17].…”
Section: Discussionunclassified
“…Параметры интрастромальных колец MyoRing рассчитывали по номограмме А. Daxer (2007) [15], учитывающей среднее значение кератометрии и минимальную толщину роговицы.…”
Section: материал и методыunclassified