2008
DOI: 10.1097/ico.0b013e31816a3591
|View full text |Cite
|
Sign up to set email alerts
|

Inflammatory Response to Contact Lenses in Patients With Keratoconus Compared With Myopic Subjects

Abstract: Wearing RGP CLs induces overexpression of IL-6, TNF-alpha, ICAM-1, and VCAM-1 in the tears of patients with keratoconus. These increased levels are higher in cases with severe keratoconus.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

8
85
2
4

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 121 publications
(99 citation statements)
references
References 29 publications
8
85
2
4
Order By: Relevance
“…102 They could not detect by multiplex immuno-bead assay the levels IL-17 in tears of keratoconus patients, but they found an increase by conventional ELISA on a limited number of pooled tear samples. In addition, they found lower levels of TNF-α, an observation that disagrees with reports from Lema et al 20,21,22 and Balasubramanian et al 18 The possible reasons for this disparity could be either artefactual differences in the antibody-based assays or real differences between patient populations. 103 Whether the altered protein composition of tears in eyes suffering from keratoconus is an effect of events in the corneal epithelium or has a direct influence in the development of the disease remains to be elucidated.…”
Section: Corneal Stroma Compositioncontrasting
confidence: 55%
See 4 more Smart Citations
“…102 They could not detect by multiplex immuno-bead assay the levels IL-17 in tears of keratoconus patients, but they found an increase by conventional ELISA on a limited number of pooled tear samples. In addition, they found lower levels of TNF-α, an observation that disagrees with reports from Lema et al 20,21,22 and Balasubramanian et al 18 The possible reasons for this disparity could be either artefactual differences in the antibody-based assays or real differences between patient populations. 103 Whether the altered protein composition of tears in eyes suffering from keratoconus is an effect of events in the corneal epithelium or has a direct influence in the development of the disease remains to be elucidated.…”
Section: Corneal Stroma Compositioncontrasting
confidence: 55%
“…18,21,23,75,93,125 There is also a decrease in the levels of several antioxidant or anti-inflammatory molecules: SOD, glutathione, lactoferrin, IgA, and IL-10. 19,20,106,[108][109][110]144 An important decrease in the level of protease inhibitors such as cystatins (inhibitors of cysteine proteases) and TIMP-1 (inhibitor of MMPs) have also been reported. 95,96,101,[129][130][131] The increased activity of several proteolytic enzymes results in higher concentrations of ROS, RNS, cytotoxic aldehydes (CAs) and peroxynitrates (Ps) (which decreases the activity of TIMP-1 and increase MMP-2), 63,143,144,146,149 and given the lower production of SOD 143 possibly related to IL-1α, 158 an environment with high oxidative stress and low pH is formed, causing an increase in the activation of the caspases (caspase-9 and -12), mitochondrial dysfunction (MD), and DNA damage, 156 which eventually lead to increased apoptosis.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations