Abstract: In this study, periacetabular pressures produced by different acetabular liner geometries were analyzed using Finite Element Method. The cup models consist of hemispherical metal shells fitted with normal and different chamfered polyethylene liner geometries, with the same degree of femoral head coverage. The aim of this study was to understand the influence of the design parameters of the chamfered liners, which are primarily designed to increase the range of motion (ROM) of the hip joint and reduce the risk … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…Several computational simulation software selected to conduct finite element analysis, like ANSYS [ 57 ], ABAQUS [ 65 ], COMSOL Multiphysics [ 38 , 54 ], MATLAB [ 44 ], Adams [ 66 ], and AnyBody Modelling System [ 67 ]. Both bearings of total hip arthroplasty and hip resurfacing have been studied, but mostly doing investigations on total hip arthroplasty [ 68 , 69 , 70 ]. Computational studies have been investigated to obtain results, whether on solid, fluid, or both domains.…”
Section: Computational Simulation Study On Bearing Of Hip Joint Prost...mentioning
confidence: 99%
See 2 more Smart Citations
“…Several computational simulation software selected to conduct finite element analysis, like ANSYS [ 57 ], ABAQUS [ 65 ], COMSOL Multiphysics [ 38 , 54 ], MATLAB [ 44 ], Adams [ 66 ], and AnyBody Modelling System [ 67 ]. Both bearings of total hip arthroplasty and hip resurfacing have been studied, but mostly doing investigations on total hip arthroplasty [ 68 , 69 , 70 ]. Computational studies have been investigated to obtain results, whether on solid, fluid, or both domains.…”
Section: Computational Simulation Study On Bearing Of Hip Joint Prost...mentioning
confidence: 99%
“…[ 46 ] MATLAB v. 7.0 Total hip arthroplasty Contact pressure, sliding track. Cross-shear, and wear Physiological walking condition 3D load Paul [ 64 ] FE-AA-IER Johnston and Smidt [ 80 ] Full cycle Krepelka and Toth-Taşcău [ 70 ] ANSYS Total hip arthroplasty Contact pressure Simplified walking condition Static load Bergmann et al. [ 63 ] No motion Peak loading Walking and stairs up/down Liu et al.…”
Section: Computational Simulation Study On Bearing Of Hip Joint Prost...mentioning
confidence: 99%
See 1 more Smart Citation