2020
DOI: 10.21203/rs.2.23264/v2
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: A 3D finite element analysis

Abstract: Background: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPS… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…38 Based on the above risk factors and our experience, we recommend injecting cement with a toothpaste-like viscosity in small doses multiple times (0.1 mL-0.2 mL for each injection) and under continuous fluoroscopic monitoring. 2,39,40 Some measures, including keeping the tip of screw/puncture needle away from the midline of the vertebral body, 5 reduce the volume of cement, 13 and limit the number of augmented vertebral body, 40 could also be useful to prevent cement leakage and to contribute to reductions in the incidence of PCE. Additional risk factors for PCE have also been reported in the literature.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…38 Based on the above risk factors and our experience, we recommend injecting cement with a toothpaste-like viscosity in small doses multiple times (0.1 mL-0.2 mL for each injection) and under continuous fluoroscopic monitoring. 2,39,40 Some measures, including keeping the tip of screw/puncture needle away from the midline of the vertebral body, 5 reduce the volume of cement, 13 and limit the number of augmented vertebral body, 40 could also be useful to prevent cement leakage and to contribute to reductions in the incidence of PCE. Additional risk factors for PCE have also been reported in the literature.…”
Section: Discussionmentioning
confidence: 99%
“…Since Galibert and Deramond first described the use of percutaneous vertebroplasty (PVP) for the treatment of symptomatic vertebral hemangioma in 1984, 1 cement augmentation with polymethylmethacrylate (PMMA) has been widely used in the treatment of painful vertebral fractures and osteoporosis-relat-ed degenerative spine disorders. 2 PMMA bone cement is heavily used in PVP, percutaneous kyphoplasty (PKP), and cementaugmented pedicle screw instrumentation (CAPSI) owing to the rapid and durable stability improvements of the fracture area and bone-screw interface. 3,4 However, these surgical procedures also bear a high risk of cement leakage into the vertebral venous system and fracture gaps.…”
Section: Introductionmentioning
confidence: 99%
“…We perform a biomechanical study to determine which treatment is better amongst the available treatment options for type A3.3 intertrochanteric fractures with different degrees of osteoporosis using the finite element method, thereby providing reference information for clinical treatment. STL files for smooth optimization, surface mesh reconstruction, and surface fitting [8]. After this, a 3D smooth right femur model was obtained.…”
mentioning
confidence: 99%