Proccedings of International Scientific Conference "RURAL DEVELOPMENT 2017" 2018
DOI: 10.15544/rd.2017.070
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Cylinder Design on Its Speed During Corn Ear Threshing

Abstract: Technological and structural parameters of a threshing unit must ensure the highest possible quality of its operation under minimum input and cost. The aim of the study was to estimate the variation of speed of threshing cylinder with two different shapes of filler plates (FP-I and FP-II) under various corn ear feed rate into combine harvester. Threshing cylinder speed (frequency of rotation) nb (min-1) was measured simultaneously each 0.075 s using stationary tangential single-cylinder threshing unit located … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 3 publications
0
9
0
Order By: Relevance
“…The torque of the threshing resistance was measured using a force sensor (Scaime ZFA 2000 N), which was placed between the unit frame and the lever connected to the stator of the electric motor [27]. The rotor shaft rotates in two bearing units attached to the frame of the threshing unit using bolts.…”
Section: Methodology and Means Of The Experimentsmentioning
confidence: 99%
See 4 more Smart Citations
“…The torque of the threshing resistance was measured using a force sensor (Scaime ZFA 2000 N), which was placed between the unit frame and the lever connected to the stator of the electric motor [27]. The rotor shaft rotates in two bearing units attached to the frame of the threshing unit using bolts.…”
Section: Methodology and Means Of The Experimentsmentioning
confidence: 99%
“…The output signal of the sensor was amplified using a Scaime CPJ amplifier and subsequently transmitted to the modified converter board (K8055N). The force applied to the rear part of the concave was measured using two Scaime ZFA 5000 N tension-compression force sensors 17 [27] fitted on rods holding the rear part of the concave. These sensors were capable of measuring loads of up to 5000 N. The total error of the sensor and the amplifier was 0.03% of the maximum measurement value.…”
Section: Methodology and Means Of The Experimentsmentioning
confidence: 99%
See 3 more Smart Citations