2022
DOI: 10.3390/jcm11133846
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study

Abstract: The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 39 publications
0
3
0
Order By: Relevance
“…For optimization of radiation dose, several previous studies [34][35][36] concluded that decreasing tube current in the presence of metallic objects may increase the magnitude of artifacts but has no signi cant effect on the diagnostic ability of CBCT images. Fontenele et al [34] showed that decreasing the tube current had no effect on the detection accuracy of vertical root fractures in the endodontically treated teeth next to zirconium implants.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For optimization of radiation dose, several previous studies [34][35][36] concluded that decreasing tube current in the presence of metallic objects may increase the magnitude of artifacts but has no signi cant effect on the diagnostic ability of CBCT images. Fontenele et al [34] showed that decreasing the tube current had no effect on the detection accuracy of vertical root fractures in the endodontically treated teeth next to zirconium implants.…”
Section: Discussionmentioning
confidence: 99%
“…Fontenele et al [34] showed that decreasing the tube current had no effect on the detection accuracy of vertical root fractures in the endodontically treated teeth next to zirconium implants. Also, Sawicki et al [35] found that the difference in tube current didn't affect the assessment of peri-implant bone level. Based on these ndings, we chose 12 mA (the highest mA offered by the CBCT machine used) for HD-CBCT and 2 mA (the least mA offered by the CBCT machine used) for LD-CBCT.…”
Section: Discussionmentioning
confidence: 99%
“…Fontenele et al [ 35 ] showed that decreasing the tube current had no effect on the detection accuracy of vertical root fractures in the endodontically treated teeth next to zirconium implants. Also, Sawicki et al [ 36 ] found that the difference in tube current didn’t affect the assessment of peri-implant bone level. Based on these findings, we chose 12 mA (the highest mA offered by the CBCT machine used) for HD-CBCT and 2 mA (the least mA offered by the CBCT machine used) for LD-CBCT.…”
Section: Discussionmentioning
confidence: 99%