Influence of finite spatial coherence on ptychographic reconstruction

Abstract: X-ray ptychography is an ultrahigh-resolution scanning coherent diffractive imaging technique, allowing quantitative measurements of extended samples and a simultaneous reconstruction of the illuminating wavefront. Recent development of the mixed-state reconstruction algorithm has triggered a certain interest in utilizing partially coherent X-ray sources for ptychography. Here, we study how finite spatial coherence influences the reconstructed image of a test structure. Our work shows that use of a highly cohe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…The characteristics of the three MX beamlines at PETRA III are summarized in Table 1. 2.2. Beamline P11 @ DESY DESY beamline P11 provides two state-of-the-art endstations for structural investigations of biological samples at different length scales: an X-ray microscope with a resolution of up to 10 nm [9,10,11] and a crystallography experiment. The crystallography endstation (shown in Figure 2) is operated between 5.5 keV and 30 keV and provides full SAD/MAD capability.…”
Section: 1overviewmentioning
confidence: 99%
“…The characteristics of the three MX beamlines at PETRA III are summarized in Table 1. 2.2. Beamline P11 @ DESY DESY beamline P11 provides two state-of-the-art endstations for structural investigations of biological samples at different length scales: an X-ray microscope with a resolution of up to 10 nm [9,10,11] and a crystallography experiment. The crystallography endstation (shown in Figure 2) is operated between 5.5 keV and 30 keV and provides full SAD/MAD capability.…”
Section: 1overviewmentioning
confidence: 99%
“…We used a self-developed scanning transmission X-ray microscope at photon energies slightly above Fe K absorption edge (7.112 keV), which is explained in detail in Supplementary Method 5. Horizontal spatial coherence was enhanced by defocussing the X-ray beam with convexly bent horizontally deflecting X-ray mirrors that are components of P11 optics 57 .…”
Section: Methodsmentioning
confidence: 99%
“…However, low coherence, similarly to setup vibrations or insufficient diffraction sampling, leads to loss of speckle visibility. Therefore the actual quality improvement provided by the additional flux of a low coherence illumination could be smaller than the expected value or even counterproductive 38 . On the other hand, one should not use more coherence than needed 32 as this leads to unnecessary filtering of the incoming intensity and decrease of the signal-to-noise ratio, an optimum has to be found.…”
Section: Scanning Precisionmentioning
confidence: 96%