2014
DOI: 10.1016/j.jmbbm.2013.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Influence of glucocorticosteroids on the biomechanical properties of in-vivo rabbit cornea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 31 publications
0
11
0
2
Order By: Relevance
“… 37 Corneal biomechanics is depth dependent, and tensile strength in the anterior stroma is nearly twice that of the posterior stroma. 32 To model corneal mechanical behavior, we employed a first-order hyperelastic Ogden material model: 25 , 30 , 38 where , , and represent the deviatoric principal stretches = J –1/3 λ k ( k = 1, 2, 3); λ 1 , λ 2 , and λ 3 are the principal stretches; J = λ 1 λ 2 λ 3 ; and α , µ , and D are the material constants. D is a compressibility parameter whose value depends on Poisson's ratio ( ν ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“… 37 Corneal biomechanics is depth dependent, and tensile strength in the anterior stroma is nearly twice that of the posterior stroma. 32 To model corneal mechanical behavior, we employed a first-order hyperelastic Ogden material model: 25 , 30 , 38 where , , and represent the deviatoric principal stretches = J –1/3 λ k ( k = 1, 2, 3); λ 1 , λ 2 , and λ 3 are the principal stretches; J = λ 1 λ 2 λ 3 ; and α , µ , and D are the material constants. D is a compressibility parameter whose value depends on Poisson's ratio ( ν ).…”
Section: Methodsmentioning
confidence: 99%
“…37 Corneal biomechanics is depth dependent, and tensile strength in the anterior stroma is nearly twice that of the posterior stroma. 32 To model corneal mechanical behavior, we employed a first-order hyperelastic Ogden material model: 25,30,38…”
Section: Corneal Materials Propertiesmentioning
confidence: 99%
“…After carrying out measurements using the ORA, the corneas were extracted from the eye globes with a 3-mm ring of scleral tissue and all other ocular components were removed. As described previously [ 25 - 27 ], the corneas were mounted onto a custom designed pressure chamber of an inflation test rig using a mechanical clamp and cyano-acrylate glue to provide watertight connection along their ring of scleral tissue. Care was taken to avoid damage to the epithelium and endothelium.…”
Section: Methodsmentioning
confidence: 99%
“…19 A relação entre níveis de glicocorticóides e alteração estruturais da córnea vem sendo pesquisada cada vez mais. 106,135 Existem evidências da diminuição da rigidez de córneas de coelhos que foram tratados com colírios de glicocorticóides. 135 Brown et al 106 demonstraram um aumento significativo da ação lítica de colagenases em córneas de coelhos causado pelo cortisol.…”
Section: Citocinas Inflamatórias Lacrimais No Ceratoconeunclassified
“…106,135 Existem evidências da diminuição da rigidez de córneas de coelhos que foram tratados com colírios de glicocorticóides. 135 Brown et al 106 demonstraram um aumento significativo da ação lítica de colagenases em córneas de coelhos causado pelo cortisol. Há evidência da associaçāo entre níveis elevados de hormônios de estresse em pacientes com apneia, que é uma doença mais prevalente em pacientes com ceratocone.…”
Section: Citocinas Inflamatórias Lacrimais No Ceratoconeunclassified