2024
DOI: 10.1016/j.prosdent.2021.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
53
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 26 publications
(53 citation statements)
references
References 40 publications
0
53
0
Order By: Relevance
“…[43][44][45] Studies have analyzed the influence of the implant depth on intraoral scanning accuracy with contradictory results reported. [43][44][45] In an in vitro study, Laohverapanich et al 43 when obtaining a half-arch scan on a partially edentulous cast with 1 implant scan body. The best accuracy values were obtained when implants had up to 6-mm depth.…”
Section: Edentulous Spacesmentioning
confidence: 99%
See 3 more Smart Citations
“…[43][44][45] Studies have analyzed the influence of the implant depth on intraoral scanning accuracy with contradictory results reported. [43][44][45] In an in vitro study, Laohverapanich et al 43 when obtaining a half-arch scan on a partially edentulous cast with 1 implant scan body. The best accuracy values were obtained when implants had up to 6-mm depth.…”
Section: Edentulous Spacesmentioning
confidence: 99%
“…Implant depth is related to clinical implant scan body height 43–45 . Studies have analyzed the influence of the implant depth on intraoral scanning accuracy with contradictory results reported 43–45 . In an in vitro study, Laohverapanich et al 43 evaluated the influence of the implant depth (3, 6, and 9 mm) on the scanning accuracy of four IOSs (Omnicam from Dentsply Sirona, Trios 3 from 3Shape A/S, True Definition from 3 M ESPE, and DWIO from Dental Wings) when obtaining a half‐arch scan on a partially edentulous cast with 1 implant scan body.…”
Section: Patient Factorsmentioning
confidence: 99%
See 2 more Smart Citations
“…Similarly, complete‐arch scans by using IOSs for fabricating complete‐arch tooth‐ and implant‐supported rehabilitations have shown contradictory results in the literature regarding reliability and accuracy 31–35,41,42 . Different techniques have been described to improve the scanning accuracy of complete‐arch implant digital scans; however, due to the limited clinical data published, a systematic recommendation of complete‐arch implant digital scans by using IOSs is difficult 43–45 …”
Section: Introductionmentioning
confidence: 99%