Problems of Atomic Science and Technology 2021
DOI: 10.46813/2021-131-057
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Longitudinal Magnetic Field in the MPC Channel on the Density of Generated Plasma Stream

Abstract: The paper is devoted to experimental measurements and analysis of parameters of the plasma streams generated by magnetoplasma compressor (MPC) upgraded with an external axial magnetic field. Influence of the external axial magnetic field of 0.24 T on helium plasma streams (P=2 Torr) has been studied. The measurements of average electron density distributions were performedboth with and without an external axial B-field. Distributions of plasma electron density Ne (L) were measured with spectroscopy in the plas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…Optical spectroscopy was used for the determination of plasma parameters (electron density and temperature) in front of exposed surfaces and the studies of the target impurity behavior in the plasma shield during a plasma surface interaction. It should be noted that the hydrogen spectral line H (4861 Å), as well as the line of He II with a wavelength of 4685 Å were used to evaluate plasma density [9,10]. Exposition time was 10 s.…”
Section: Experimental Facility and Diagnosticsmentioning
confidence: 99%
“…Optical spectroscopy was used for the determination of plasma parameters (electron density and temperature) in front of exposed surfaces and the studies of the target impurity behavior in the plasma shield during a plasma surface interaction. It should be noted that the hydrogen spectral line H (4861 Å), as well as the line of He II with a wavelength of 4685 Å were used to evaluate plasma density [9,10]. Exposition time was 10 s.…”
Section: Experimental Facility and Diagnosticsmentioning
confidence: 99%
“…This transient plasma has drawn attention from the scientific community due to its successful application in different fields of fusion research such as plasma material interaction (PMI) study [5,6], plasma refueling [7], the study of vapor shielding effects [8,9], simulation of astrophysical plasmas [10]. Similar types of devices such as QSPA-M [11], Magneto plasma compressor (MPC) [12], and MK-200UG [13] has also an external magnetic field to confine and collimate the plasma beam for fusion-related PMI study. Garkusha et al reported an increase in plasma material shielding layer in QSPA-M with a magnetic field [9].…”
Section:  Introductionmentioning
confidence: 99%