2018
DOI: 10.1016/j.buildenv.2018.08.039
|View full text |Cite
|
Sign up to set email alerts
|

Influence of natural ventilation rate on indoor PM2.5 deposition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 71 publications
(27 citation statements)
references
References 72 publications
1
26
0
Order By: Relevance
“…However, none of these studies considered the possibility of the aerosols carrying any charge, and what effect this would have on measured deposition rates. This was also the case in a number of other aerosol deposition studies (Abadie et al, 2001;El Hamdani et al, 2008;Liu et al, 2018;Wang et al, 2019).…”
Section: Accepted Manuscriptsupporting
confidence: 59%
“…However, none of these studies considered the possibility of the aerosols carrying any charge, and what effect this would have on measured deposition rates. This was also the case in a number of other aerosol deposition studies (Abadie et al, 2001;El Hamdani et al, 2008;Liu et al, 2018;Wang et al, 2019).…”
Section: Accepted Manuscriptsupporting
confidence: 59%
“…Five Danish homes are reported to have all‐season average of 0.36‐1.97 hours −1 . Chen et al assumed air exchange rate with open windows to be higher than that with closed windows by 1.5 hours −1 . Based on these studies, a baseline value of 0.7 hours −1 is assumed in the present study, and a sensitivity test is carried out with a lower value of 0.4 hours −1 and a higher value of 2 hours −1 .…”
Section: Methodsmentioning
confidence: 93%
“…As the size distribution of PM 2.5 is often unavailable, we have treated PM 2.5 as monodisperse particles with a characteristic diameter ( d p ). Since the size distribution of indoor PM 2.5 normally peaks at 0.3‐1 μm, we use a median value of 0.6 μm as a baseline value for its peak size and test sensitivity by varying it to 0.3 μm and 1 μm. A p and V p are equal to πdp2 and πdp3/6, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This longer lifetime of particles may pose a signi cantviral exposure to healthcare personnel, especially in indoorenvironments. PM 2.5 can also be deposited in indoorenvironments such as hospitals' ooring 17,18 and anysurface materials 19,20 . This ne particulate matter isreadily propagated by tiny turbulent eddies in the air that arisefrom physical activities such as human movements andwalking 21,,22 .…”
Section: Main Textmentioning
confidence: 99%