Influence of oil–paper configuration on electric field distribution of main insulation structure on valve‐side winding of UHV‐DC converter transformer

Abstract: The main insulation structure of the valve‐side winding of converter transformer bears the effect of AC and DC superimposed voltage during operation. The electric field intensity in the pressboard is much higher than that in the pressboard in the AC transformer. This condition increases the probability of failure of insulation structure. Therefore, the design and optimization of the main insulation structure of the valve‐side winding are keys to ensure the stable operation of converter transformer. This study … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…Ultra high voltage direct current (UHVDC) transmission is the preferred long-distance DC transmission method in China owing to its advantages of low line loss, low cost, reliable system operation, and stability [1]. As the core equipment of the DC transmission system, with the rapid increase in power load, the capacity of a converter transformer needs to be increased, which implies that the transmission voltage level should be increased from ± 800 kV to ± 1100 kV [2]. Compared with conventional AC transformers, converter trans-The associate editor coordinating the review of this manuscript and approving it for publication was Guillaume Parent .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ultra high voltage direct current (UHVDC) transmission is the preferred long-distance DC transmission method in China owing to its advantages of low line loss, low cost, reliable system operation, and stability [1]. As the core equipment of the DC transmission system, with the rapid increase in power load, the capacity of a converter transformer needs to be increased, which implies that the transmission voltage level should be increased from ± 800 kV to ± 1100 kV [2]. Compared with conventional AC transformers, converter trans-The associate editor coordinating the review of this manuscript and approving it for publication was Guillaume Parent .…”
Section: Introductionmentioning
confidence: 99%
“…formers have a specific insulating structure and operating condition: the valve-side winding is subjected to AC, DC, impulse, and combined AC-DC voltage (CADV) during operation, which makes their operating conditions more complex and changeable [2], [3].…”
Section: Introductionmentioning
confidence: 99%
“…Good oil-paper insulation is a prerequisite for maintaining reliable operation of power transformers [1,2]. However, in the operation of transformers, the oil-paper insulation gradually degrades and fails [3,4]. The objective of transformer oilpaper insulation degradation modelling is to predict its future degradation trend, degree of degradation, and failure time range by establishing a degradation model, and thereby provide a reference for the formulation of a power transformer insulation maintenance plan [5,6].…”
Section: Introductionmentioning