2019
DOI: 10.3390/app9163231
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Process Parameters in Laser Piercing

Abstract: This work addresses the analysis of the influence of process parameters in laser piercing for mild steel, stainless steel, and aluminum thick sheets, carried out by the monitorization of the signal with a photodiode installed coaxially in the cutting head. The sensor captures the infrared or visible signal emitted during the piercing. The relationship between the intensity of the signal and the parameter values was analyzed, distinguishing between soft and fast piercings. The results permit the optimization of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 14 publications
0
3
0
1
Order By: Relevance
“…IR monitoring signals showed a contrary effect (0.7 V vs. 0.4 V, for 5 and 10 mm). In this case, the measured infrared signal was related to temperature [25], which decreased in the thicker plate as a consequence of heat conduction phenomena, according to the literature [27].…”
Section: Resultsmentioning
confidence: 70%
See 2 more Smart Citations
“…IR monitoring signals showed a contrary effect (0.7 V vs. 0.4 V, for 5 and 10 mm). In this case, the measured infrared signal was related to temperature [25], which decreased in the thicker plate as a consequence of heat conduction phenomena, according to the literature [27].…”
Section: Resultsmentioning
confidence: 70%
“…To analyze the influence of the thickness in the registered signal, two aluminum plates of 5 and 10 mm thickness were cut with N 2 at 5 kW, with the velocity, gas pressure, and focal position specified in Table 1. Comparing VIS monitoring signals, the 10 mm thick plate displayed a higher value than the thinner one (0.6 V vs. 0.15 V), explained as a consequence of more vapor plume formation [25] during the cutting process of the thicker plate, and thus, an increase in VIS signal. IR monitoring signals showed a contrary effect (0.7 V vs. 0.4 V, for 5 and 10 mm).…”
Section: Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…Kesim parametrelerinden frekansın değişmesinin kesim yüzeyine etkisinin olmadığı görülmüştür. Frekans piercing (delme, patlatma) parametrelerinde, patlatma çaplarının değiştirilmesi için kullanılmaktadır [12].…”
Section: Materyal Ve Yöntemunclassified