“…13,14 However, squeaking has been considered a relevant complication after ceramic-on-ceramic THAs since 2007. 7,15 Factors reported to be related to squeaking include patient, 15 surgical, 6 postoperative ROM, 16,17 and implant factors, 18,19 and those inherent to the bearing surface itself, such as microseparation, 8 lubrication disruption, 20 metal transfer, and a third-body mechanism. 21 The exact etiology of squeaking remains unclear and may be multifactorial.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…13,14 However, squeaking has been considered a relevant complication after ceramic-on-ceramic THAs since 2007. 7,15 Factors reported to be related to squeaking include patient, 15 surgical, 6 postoperative ROM, 16,17 and implant factors, 18,19 and those inherent to the bearing surface itself, such as microseparation, 8 lubrication disruption, 20 metal transfer, and a third-body mechanism. 21 The exact etiology of squeaking remains unclear and may be multifactorial.…”
Section: Discussionmentioning
confidence: 99%
“…This design may lead to earlier femoral neck impingement and joint subluxation, which may cause metal transfer to the ceramic head. 19 However, the Lineage Acetabular Cup system (Wright Medical Technology, Inc), which has a ceramic insert seated flush to the titanium shell, was used in the current study. Swanson et al 19 reported a 0% (0/29 patients) incidence of squeaking using the Lineage Acetabular Cup.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Trident acetabular cups paired with Stryker Accolade femoral stems showed a dramatically higher incidence of squeaking. They concluded that prosthetic design plays a key role in squeaking occurrence [35]. Another significant cause of squeaking is cup design that results in premature femoral neck-acetabular component rim impingement such as the presence of modular ceramic liner designs that are placed within a titanium encasement with extended rims [29,34].…”
Section: Swanson Et Al Reviewed 233 Patients Comparing 4 Implant Commentioning
confidence: 99%
“…Обращает на себя внимание ряд исследований по изучению оптимальных конструкций имплантатов и методик ЭТС для пациентов с ревматическими поражениями тазобедренного сустава [50][51][52]. В качестве информации и с целью повышения осведомленности населения о результатах ЭТС используют положительные данные динамики качества жизни до и после оперативного лечения [53].…”
unclassified