2022
DOI: 10.1016/j.cscm.2022.e01316
|View full text |Cite
|
Sign up to set email alerts
|

Influence of self-ignition coal gangue on properties of foam concrete with steam curing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 35 publications
0
3
0
Order By: Relevance
“…Researchers separately added activated CG, 1 calcined CG, 69,70 and natural CG [71][72][73] into Portland cement and found that Portland cement with activated CG had a higher capillary pore content than cement containing fly ash, whereas its strength and shrinkage values were lower. The gel porosity of a CG composite and that of fly ash composite are obviously higher than that of ordinary paste, and the micro-and macropore sizes are larger than those of ordinary paste.…”
Section: Cement-based Porous Materialsmentioning
confidence: 99%
“…Researchers separately added activated CG, 1 calcined CG, 69,70 and natural CG [71][72][73] into Portland cement and found that Portland cement with activated CG had a higher capillary pore content than cement containing fly ash, whereas its strength and shrinkage values were lower. The gel porosity of a CG composite and that of fly ash composite are obviously higher than that of ordinary paste, and the micro-and macropore sizes are larger than those of ordinary paste.…”
Section: Cement-based Porous Materialsmentioning
confidence: 99%
“…Thermal conductivities of 0.04~0.06 W/(m•K) could be obtained at 88.5~95.4% porosity, but high porosity means a low content of the solid phase in foamed concrete and a low heat capacity, thus weakening the thermal comfort of indoor building and the mechanical strength [15]. To improve the mechanical strength and reduce the thermal conductivity of foamed concrete, many approaches have been conducted and investigated, as shown in Table 1 [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34]; however, these approaches could not significantly enhance insulation performance under suitable mechanical strength [35,36]. Other approaches were also developed under the suitable content of the cement matrix (suitable dry density).…”
Section: Introductionmentioning
confidence: 99%
“…The main pore structure parameters of FC are porosity, average pore size, pore size distribution, roundness value. However, FC suffers from low strength, cracking, high water absorption and drying shrinkage due to the presence of uniform porous structure and lack of coarse aggregates [17,18]. In FC, the addition of three-dimensional randomly distributed fibers can change the typical brittle behavior into an elastic-plastic one, thus improving the compressive strength, tensile strength and ductility of FC.…”
Section: Introductionmentioning
confidence: 99%